An investigation on dehumidification and heat transfer characteristics of a minichannel heat exchanger for heat pump system of electric vehicles
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The MCHX model using the distributed parameter method shows excellent prediction accuracy with absolute errors of 4% and 10% for dehumidification rate and heat transfer rate, respectively.
“The model shows excellent prediction ac curacy with absolute errors of 4% and 10% for dehumidification rate and heat transfer rate, respectively.”
From Thermal-hydraulic and drainage performance of microchannel heat exchangers for refrigeration and heat pump systems under frosting, defrosting, and wet conditions: A comprehensive review (2023) · cites this paper as [117]
Section 2.4 describes a distribution-parameter model, but the Conclusions report the error bounds in the opposite order: ±4% for heat transfer rate (HTR) and ±10% for dehumidification rate (DHR). Section 3.3 likewise reports maximum absolute errors of 3.5% for HTR and 9.6% for DHR. (LLM, conf=0.94)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 40 · Cited by 6
Research works printed but not linked: 30
- Zhang Z, Wang J, Feng X, Chang L, Chen Y, Wang X. The solutions to electric vehicle air conditioning systems: a review. Renew Sustain Energy Rev. 2018;91:443-463.
- Liu J, Zou H, Zhang G, Zhang X, Tian C. Analysis of maximum return air ratio on no-fogging condition by in-cabin climate simulation for EV. Energy Procedia. 2017;105:2445-2450.
- Dancaa P, Vartiresa A, Dogeanu A. An overview of current methods for thermal comfort assessment in vehicle cabin. Energy Procedia. 2016;85:162-169.
- Yang Y, Huang Y, Zhao J. Optimization of the automotive air conditioning strategy based on the study of dewing phenome- non and defogging progress. Appl Therm Eng. 2020;169:114932.
- Zhang G, Zou H, Qin F, Xue Q, Tian C. Investigation on an improved heat pump AC system with the view of return air uti- lization and anti-fogging for electric vehicles. Appl Therm Eng. 2017;115:726-735.
- Zhang L, Hashimoto K, Hasegawa H, Saikawa M. Performance analysis of a heat pump system with integrated desiccant for electric vehicles. Int J Refrig. 2018;86:154-162.
- Alahmer A. Thermal analysis of a direct evaporative cooling sys- tem enhancement with desiccant dehumidification for vehicular air conditioning. Appl Therm Eng. 2016;98:1273-1285.
- Chai S, Sun X, Zhao Y, Dai Y. Experimental investigation on a fresh air dehumidification system using heat pump with desic- cant coated heat exchanger. Energy. 2019;171:306-314.
- Hua L, Ge T, et al. Extremely high efficient heat pump with desic- cant coated evaporator and condenser. Energy. 2019;170:569-579.
- Na S, Chung Y, Kim M. Performance analysis of an electric vehicle heat pump system with a desiccant dehumidifier. Energ Conver Manage. 2021;236:114083.
- Wang D, Cao X, Li X, Li Y, Wang X. Experimental investiga- tion of a part air dehumidification cascade-like heat pump dry- ing system. Int J Refrig. 2021;131:235-243.
- Wiksten R, Assad M. Heat and mass transfer analysis of a wavy fin-and-tube heat exchanger under fully and partially wet sur- face conditions. Int J Thermal Sci. 2010;49:349-355.
- Liang Y, Liu C, et al. Experimental and simulation study on the air side thermal hydraulic performance of automotive heat exchangers. Appl Therm Eng. 2015;87:305-315.
- Tian Z, Ma L, Gu B, Yang L, Liu F. Numerical model of a par- allel flow minichannel evaporator with new flow boiling heat transfer correlation. Int J Refrig. 2016;63:1-13.
- Torregrosa-Jaime B, Corber an J, et al. Thermal characterisation of compact heat exchangers for air heating and cooling in elec- tric vehicles. Appl Therm Eng. 2017;115:774-781.
- Venegas T, Qu M, Nawaz K, Wang L. Critical review and future prospects for desiccant coated heat exchangers: mate- rials, design, and manufacturing. Renew Sustain Energy Rev. 2021;151:111531.
- Zhao L, Wang R, Ge T. Desiccant coated heat exchanger and its applications. Int J Refrig. 2021;130:217-232.
- Wang C, Ji X, Yang B, Zhang R, Yang D. Study on heat transfer and dehumidification performance of desiccant coated micro- channel heat exchanger. Appl Therm Eng. 2021;192:116913.
- Han X, Zou H, Kang W, Xu H, Chen Y, Tian C. Experimental investigation on vapor injection ASHP for electric rail vehicles in cold region. Appl Therm Eng. 2019;153:473-482.
- Li W, Liu R, Liu Y, Wang D, Shi J, Chen J. Performance evalu- ation of R1234yf heat pump system for an electric vehicle in cold climate. Int J Refrig. 2020;115:117-125.
- Shah MM. Improved correlation for heat transfer during con- densation in conventional and mini/micro channels. Int J Refrig. 2019;98:222-237.
- Moffat RJ. Describing the uncertainties in experimental results. Exp Thermal Fluid Sci. 1998;1:3-17.
- Sepehr S, Masoud D. Modeling and multi-objective optimiza- tion of parallel flow condenser using evolutionary algorithm. Appl Energy. 2011;88:1568-1577.
- Tian Z, Gu B, Yang L, Liu F. Performance prediction for a par- allel flow condenser based on artificial neural network. Appl Therm Eng. 2014;63:459-467.
- Kim MH, Bullard CW. Air-side performance of brazed alumi- num heat exchangers under dehumidifying conditions. Int J Refrig. 2002;25:924-934.
- Bertsch SS, Groll EA, Garimella SV. A composite heat transfer correlation for saturated flow boiling in small channels. Int J Heat Mass Transfer. 2009;52:2110-2118.
- Kandlikar SG, Balasubramanian P. An extension of the flow boiling correlation to transition, laminar, and deep laminar flows in minichannels and microchannels. Heat Transfer Eng. 2004;25:86-93.
- Zhang M, Webb R. Correlation of two-phase friction for refrig- erants in small-diameter tubes. Exp Thermal Fluid Sci. 2001;25: 131-139.
- Kim S, Mudawar I. Universal approach to predicting saturated flow boiling heat transfer in mini/micro-channels part II. Two- phase heat transfer coefficient. Int J Heat Mass Transfer. 2013; 64:1239-1256.
- Liu N, Li J, Sun J, et al. Heat transfer and pressure drop during condensation of R152a in circular and square microchannels. Exp Thermal Fluid Sci. 2013;47:60-67. How to cite this article: Yu J, Su L, Li K, Fang Y. An investigation on dehumidification and heat transfer characteristics of a minichannel heat exchanger for heat pump system of electric vehicles. Int J Energy Res. 2022;46(13):18294-18311. doi:10.1002/er.8445
- Authors
- Yu, J., Su, L., Li, K., & Fang, Y.
- Affiliations
- University of Shanghai for Science and Technology (CN)
- Corresponding author
- Su, Lin
- Venue
- International Journal of Energy Research
- Publisher
- Wiley
- Published
- 2022-07-29
- Volume
- 46
- Issue
- 13
- Pages
- 18294-18311
- ISSN
- 0363-907X (ISSN-L)
- 1099-114X
- OpenAlex
- W4288709701
- Cited by
- 6
- References
- 40
- Citations by year
- 2026: 2 · 2025: 1 · 2023: 2 · 2022: 1
- FWCI
- 0.32
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- International Journal of Energy Research (publishedVersion)
- SSRN Electronic Journal (publishedVersion)
- Funders
- National Natural Science Foundation of China (51876130, 51906158, 52076084)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- mini-channel heat exchanger, dehumidification, heat pumps, electric vehicles, cabin climate control, distributed parameter model, heat and mass transfer, parallel flow, refrigerant mass flow rate, evaporator, test bench
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review