The DOI matches its Crossref record.
Improved method for estimating bioconcentration/bioaccumulation factor from octanol/water partition coefficient
Abstract
A compound's bioconcentration factor (BCF) is the most commonly used indicator of its tendency to accumulate in aquatic organisms from the surrounding medium. Because it is expensive to measure, the BCF is generally estimated from the octanol/water partition coefficient (Kow), but currently used regression equations were developed from small data sets that do not adequately represent the wide range of chemical substances now subject to review. To develop an improved method, we collected BCF data in a file that contained information on measured BCFs and other key experimental details for 694 chemicals. Log BCF was then regressed against log Kow and chemicals with significant deviations from the line of best fit were analyzed by chemical structure. The resulting algorithm classifies a substance as either nonionic or ionic, the latter group including carboxylic acids, sulfonic acids and their salts, and quaternary N compounds. Log BCF for nonionics is estimated from log Kow and a series of correction factors if applicable; different equations apply for log Kow 1.0 to 7.0 and >7.0. For ionics, chemicals are categorized by log Kow and a log BCF in the range 0.5 to 1.75 is assigned. Organometallics, nonionics with long alkyl chains, and aromatic azo compounds receive special treatment. The correlation coefficient (r2 = 0.73) and mean error (0.48) for log BCF (n = 694) indicate that the new method is a significantly better fit to existing data than other methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rosenbaum, R. K., Bachmann, T. M., Gold, L. S., Huijbregts, M. A. J., Jolliet, O., Juraske, R., Koehler, A., Larsen, H. F., MacLeod, M., Margni, M., et al. (2008) · The International Journal of Life Cycle Assessment · doi:10.1007/s11367-008-0038-4 · Cited by 31
Metadata
- Authors
- Meylan, W. M., Howard, P. H., Boethling, R. S., Aronson, D., Printup, H., & Gouchie, S.
- Venue
- Environmental Toxicology and Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-04-01
- Volume
- 18
- Issue
- 4
- Pages
- 664-672
- ISSN
- 0730-7268 (ISSN-L)
- 1552-8618
- OpenAlex
- W2002842896
- Cited by
- 432
- References
- 0
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved method for estimating bioconcentration/bioaccumulation factor from octanol/water partition coefficient. https://app.cochat.ai/papers/10.1002/etc.5620180412
- The paper
- Meylan, W. M., Howard, P. H., Boethling, R. S., Aronson, D., Printup, H., & Gouchie, S. (1999). Improved method for estimating bioconcentration/bioaccumulation factor from octanol/water partition coefficient. Environmental Toxicology and Chemistry. https://doi.org/10.1002/etc.5620180412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.