CoChat

Development of 1 kW‐class Ammonia‐fueled Solid Oxide Fuel Cell Stack

Open access
Kishimoto, M., Muroyama, H., Suzuki, S., Saito, M., Koide, T., Takahashi, Y., Horiuchi, T., Yamasaki, H., Matsumoto, S., Kubo, H., Takahashi, N., Okabe, A., Ueguchi, S., Jun, M., Tateno, A., Matsuo, T., Matsui, T., Iwai, H., Yoshida, H., Eguchi, K. · 2020 · Fuel Cells
Cited by 141

The DOI matches its Crossref record.

Abstract

Power generation performance and long‐term durability of ammonia‐fueled solid oxide fuel cell (SOFC) systems are investigated with SOFC stacks consisting of 30 planar anode‐supported cells. SOFC systems with three different operation modes are employed: direct ammonia, external decomposition and autothermal decomposition. A novel BaO/Ni/Sm 2 O 3/MgO catalyst is newly developed for the external ammonia cracker, whereas a Co‐Ce‐Zr composite oxide catalyst is used for the autothermal ammonia cracker. Initial performance measurement and 1,000 h long‐term durability test of the stacks are conducted. The stack fueled with direct ammonia achieves 1 kW power output with 52% direct current (DC) electrical efficiency; a slight decrease in its performance compared with the stack with the mixture fuel of hydrogen and nitrogen is attributed to the decrease in the stack temperature caused by the endothermic ammonia decomposition reaction. The external ammonia cracker helps to maintain the stack temperature, improving the initial performance of the stack. The stack performance with the autothermal ammonia cracker is also comparable to those with the other operation modes. It is also demonstrated that the stacks fueled with ammonia have excellent stability during the long‐term tests and 57% energy conversion efficiency at ca. 700 W electrical output is achieved with the external ammonia cracker.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/fuce.201900131

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 141

Metadata

Authors
Kishimoto, M., Muroyama, H., Suzuki, S., Saito, M., Koide, T., Takahashi, Y., Horiuchi, T., Yamasaki, H., Matsumoto, S., Kubo, H., Takahashi, N., Okabe, A., Ueguchi, S., Jun, M., Tateno, A., Matsuo, T., Matsui, T., Iwai, H., Yoshida, H., & Eguchi, K.
Venue
Fuel Cells
Publisher
Wiley
Published
2020-01-22
Volume
20
Issue
1
Pages
80-88
ISSN
  • 1615-6846 (ISSN-L)
  • 1615-6854
OpenAlex
W3003110488
Cited by
141
References
0
FWCI
5.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of 1 kW‐class Ammonia‐fueled Solid Oxide Fuel Cell Stack. https://app.cochat.ai/papers/10.1002/fuce.201900131
The paper
Kishimoto, M., Muroyama, H., Suzuki, S., Saito, M., Koide, T., Takahashi, Y., Horiuchi, T., Yamasaki, H., Matsumoto, S., Kubo, H., Takahashi, N., Okabe, A., Ueguchi, S., Jun, M., Tateno, A., Matsuo, T., Matsui, T., Iwai, H., Yoshida, H., & Eguchi, K. (2020). Development of 1 kW‐class Ammonia‐fueled Solid Oxide Fuel Cell Stack. Fuel Cells. https://doi.org/10.1002/fuce.201900131

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.