The DOI matches its Crossref record.
Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage
Open accessAbstract
Transient elastography [FibroScan (FS)] is a rapid, noninvasive, and reproducible method for measuring liver stiffness, which correlates with the degree of liver fibrosis in patients with chronic hepatitis. Whether FS is useful in the detection of preexisting liver fibrosis/cirrhosis in patients presenting with acute liver damage is unclear. Patients with acute liver damage of different etiologies were analyzed. Liver stiffness was measured during the acute phase of the liver damage and followed up to the end of the acute phase. A total of 20 patients were included in the study. In 15 of the 20 patients, initial liver stiffness values measured by FS during the acute phase of the liver damage were suggestive of liver cirrhosis. However, none of these 15 patients showed any signs of liver cirrhosis in the physical examination, ultrasound examination, or liver histology [performed in 11 of 15 (73%) patients]. A significant difference was observed in the initial bilirubin levels (5.8 ± 6.5 mg/dL versus 15.7 ± 11.8 mg/dL; P = 0.042) and age (32.4 ± 17.5 years versus 49.7 ± 15.8 years; P = 0.042) between patients with liver stiffness below or above 12.5 kPa. Six patients with initially high liver stiffness were followed up to abatement of the acute hepatitic phase; in all of them, liver stiffness values decreased to values below the cutoff value for liver cirrhosis. Conclusion: Transient elastography frequently yields pathologically high values in patients with acute liver damage and is unsuitable for detecting cirrhosis/fibrosis in these patients. (Hepatology 2007.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Noninvasive assessment of liver disease in patients with nonalcoholic fatty liver disease
Castera, L., Friedrich-Rust, M., & Loomba, R. (2019) · Gastroenterology · doi:10.1053/j.gastro.2018.12.036 · Cited by 1,494
Non-invasive evaluation of liver fibrosis using transient elastography
Castera, L., Forns, X., & Alberti, A. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.008 · Cited by 1,430
Wong, V. W.-S., Vergniol, J., Wong, G. L.-H., Foucher, J., Chan, H. L.-Y., Le Bail, B., Choi, P. C.-L., Kowo, M., Chan, A. W.-H., Merrouche, W., et al. (2010) · Hepatology · doi:10.1002/hep.23312 · Cited by 1,322
Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations
Castéra, L., Foucher, J., Bernard, P.-H., Carvalho, F., Allaix, D., Merrouche, W., Couzigou, P., & de Lédinghen, V. (2010) · Hepatology · doi:10.1002/hep.23425 · Cited by 1,159
Metadata
- Authors
- Sagir, A., Erhardt, A., Schmitt, M., & Häussinger, D.
- Venue
- Hepatology
- Published
- 2008-02
- Volume
- 47
- Issue
- 2
- Pages
- 592-595
- ISSN
- 0270-9139 (ISSN-L)
- OpenAlex
- W2027453598
- Cited by
- 513
- References
- 0
- FWCI
- 26.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage. https://app.cochat.ai/papers/10.1002/hep.22056
- The paper
- Sagir, A., Erhardt, A., Schmitt, M., & Häussinger, D. (2008). Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage. Hepatology. https://doi.org/10.1002/hep.22056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.