Cited by 11Heat Transfer and OptimizationHeat Transfer and Boiling StudiesRefrigeration and Air Conditioning Technologies

Research on corrugated multi‐louvered fins under dehumidification

Osada, Hiroshi, Aoki, Hiroshi, Ohara, Toshio, Kuroyanagi, Isao·2001·Heat Transfer—Asian Research

Abstract

To enhance automotive evaporator wet‐fin performances, the main task is to promote the draining of condensed water. An accurate and convenient apparatus estimating the fin performances has been developed. Through the measurement of corrugated multi‐louvered fin performances and the visualization of condensed water draining by this apparatus, it was clarified that fin geometries, surface coating, and evaporator installation strongly contributed to the efficiency of draining and fin performances. © 2001 Scripta Technica, Heat Trans Asian Res, 30(5): 383–393, 2001

Integrity signals

Registry

Crossref · 10.1002/htj.1025

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Authors
Osada, H., Aoki, H., Ohara, T., & Kuroyanagi, I.
Affiliations
  • Toyota Central Research and Development Laboratories (Japan) (JP)
  • Denso (Japan) (JP)
Venue
Heat Transfer—Asian Research
Publisher
Wiley
Published
2001-06-18
Volume
30
Issue
5
Pages
383-393
ISSN
  • 1099-2871 (ISSN-L)
  • 1523-1496
OpenAlex
W2039974926
Cited by
11
References
0
Citations by year
2023: 1 · 2022: 1 · 2020: 1 · 2018: 1 · 2013: 2 · 2012: 1
FWCI
1.14
Type
journal article
Language
en
Open access
closed
Locations
Heat Transfer-Asian Research (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
dehumidification, condensate drainage, fin geometry, surface coating

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review