Assessment of ovarian cancer conditions from exhaled breath
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present a pilot study that aims to examine the possibility to easily and noninvasively detect and discriminate females with ovarian cancer (OC) from females that have no tumor(s) and from females that have benign genital tract neoplasia, using exhaled breath samples. The study is based on clinical samples and data from 182 females, as follows: 48 females with OC, 48 tumor‐free controls and 86 females with benign gynecological neoplasia. Analysis of the breath samples with gas chromatography linked with mass spectrometry shows that decanal, nonanal, styrene, 2‐butanone and hexadecane could serve as potential volatile markers for OC. Analysis of the same samples with tailor‐made nanoarrays shows good discrimination between females with OC and females that have either no tumor or benign genital tract neoplasia (71% for accuracy, sensitivity and specificity). Conversely, the nanoarray output shows excellent discrimination between the OC patients and the tumor‐free controls (79% sensitivity, 100% specificity and 89% accuracy). These results suggest that the nanoarray approach might be useful to avoid unnecessary complicated or expensive tests for tumor‐free females in case of a negative result. In the case of positive result, the test will indicate with high probability the presence of OC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953 · cited 3×
“These VOCs can be found in various body fluids, such as tissue, blood, and breath.(5,8,9) Based on this principle, trained canines showed an ability to distinguish OC tissues(11) or blood samples(12) from equivalent controls with 100% sensitivity and 98% specificity.”
BackgroundSelf-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561 · cited 1×
“In contrast to GC-MS, each sensor in the nanoarray responds to all the breath compounds and the combined responses of all the sensors are then used to build a specific pattern for a specific disease.(7,8) In contrast to the GC-MS analysis the nanoarray presented discrimination between the majority of the tested groups.”
MethodSelf-citation
Cited by
Nakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citationBroza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Self-citationEvolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Electronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Self-citationAdvanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Self-citation
Metadata
- Authors
- Amal, H., Shi, D., Ionescu, R., Zhang, W., Hua, Q., Pan, Y., Tao, L., Liu, H., & Haick, H.
- Venue
- International Journal of Cancer
- Publisher
- Wiley
- Published
- 2014-09-05
- Volume
- 136
- Issue
- 6
- Pages
- E614-22
- ISSN
- 0020-7136 (ISSN-L)
- 1097-0215
- OpenAlex
- W2126879886
- Cited by
- 142
- References
- 2
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.