Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Breath testing as potential colorectal cancer screening tool: Breath test for the detection of colorectal cancer

Open access
Amal, Haitham, Leja, Marcis, Funka, Konrads, Lasina, Ieva, Skapars, Roberts, Sivins, Armands, Ancans, Guntis, Kikuste, Ilze, Vanags, Aigars, Tolmanis, Ivars, Kirsners, Arnis, Kupcinskas, Limas, Haick, Hossam·2016·International Journal of Cancer

Abstract

Although colorectal cancer (CRC) screening is included in organized programs of many countries worldwide, there is still a place for better screening tools. In this study, 418 breath samples were collected from 65 patients with CRC, 22 with advanced or nonadvanced adenomas, and 122 control cases. All patients, including the controls, had undergone colonoscopy. The samples were analysed with two different techniques. The first technique relied on gas chromatography coupled with mass spectrometry (GC-MS) for identification and quantification of volatile organic compounds (VOCs). The T-test was used to identify significant VOCs (p values < 0.017). The second technique relied on sensor analysis with a pattern recognition method for building a breath pattern to identify different groups. Blind analysis or leave-one-out cross validation was conducted for validation. The GC-MS analysis revealed four significant VOCs that identified the tested groups; these were acetone and ethyl acetate (higher in CRC), ethanol and 4-methyl octane (lower in CRC). The sensor-analysis distinguished CRC from the control group with 85% sensitivity, 94% specificity and 91% accuracy. The performance of the sensors in identifying the advanced adenoma group from the non-advanced adenomas was 88% sensitivity, 100% specificity, and 94% accuracy. The performance of the sensors in identifying the advanced adenoma group was distinguished from the control group was 100% sensitivity, 88% specificity, and 94% accuracy. For summary, volatile marker testing by using sensor analysis is a promising noninvasive approach for CRC screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ijc.29701

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 188

Metadata

Authors
Amal, H., Leja, M., Funka, K., Lasina, I., Skapars, R., Sivins, A., Ancans, G., Kikuste, I., Vanags, A., Tolmanis, I., Kirsners, A., Kupcinskas, L., & Haick, H.
Venue
International Journal of Cancer
Publisher
Wiley
Published
2015-08-07
Volume
138
Issue
1
Pages
229-236
ISSN
0020-7136 (ISSN-L)
OpenAlex
W1534268386
Cited by
188
References
3
FWCI
6.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.