The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Flexible and highly‐sensitive pressure sensor based on controllably oxidized MXene
Open accessAbstract
Conductive Ti 3 C 2 Tx MXenes have been widely investigated for the construction of flexible and highly‐sensitive pressure sensors. Although the inevitable oxidation of solution‐processed MXene has been recognized, the effect of the irreversible oxidation of MXene on its electrical conductivity and sensing properties is yet to be understood. Herein, we construct a highly‐sensitive and degradable piezoresistive pressure sensor by coating Ti 3 C 2 Tx MXene flakes with different degrees of in situ oxidation onto paper substrates using the dipping‐drying method. In situ oxidation can tune the intrinsic resistance and expand the interlayer distance of MXene nanosheets. The partially oxidized MXene‐based piezoresistive pressure sensor exhibits a high sensitivity of 28.43 kPa−1, which is greater than those of pristine MXene, over‐oxidized MXene, and state‐of‐the‐art paper‐based pressure sensors. Additionally, these sensors exhibit a short response time of 98.3 ms, good durability over 5000 measurement cycles, and a low force detection limit of 0.8 Pa. Moreover, MXene‐based sensing elements are easily degraded and environmentally friendly. The MXene‐based pressure sensor shows promise for practical applications in tracking body movements, sports coaching, remote health monitoring, and human–computer interactions. image
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
A wireless body area sensor network based on stretchable passive tags
Niu, S., Matsuhisa, N., Beker, L., Li, J., Wang, S., Wang, J., Jiang, Y., Yan, X., Yun, Y., Burnett, W., et al. (2019) · Nature Electronics · doi:10.1038/s41928-019-0286-2 · Cited by 601
Self-citation
Cited by
Recent Advances in Flexible Pressure Sensors Based on MXene Materials
Qin, R., Nong, J., Wang, K., Liu, Y., Zhou, S., Hu, M., Zhao, H., & Shan, G. (2024) · Advanced Materials · doi:10.1002/adma.202312761 · Cited by 416
Metadata
- Authors
- Ma, Y., Cheng, Y., Wang, J., Fu, S., Zhou, M., Yang, Y., Li, B., Zhang, X., & Nan, C.
- Venue
- InfoMat
- Publisher
- Wiley
- Published
- 2022-06
- Volume
- 4
- Issue
- 9
- ISSN
- 2567-3165 (ISSN-L)
- OpenAlex
- W4281764231
- Cited by
- 188
- References
- 3
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible and highly‐sensitive pressure sensor based on controllably oxidized MXene. https://app.cochat.ai/papers/10.1002/inf2.12328
- The paper
- Ma, Y., Cheng, Y., Wang, J., Fu, S., Zhou, M., Yang, Y., Li, B., Zhang, X., & Nan, C. (2022). Flexible and highly‐sensitive pressure sensor based on controllably oxidized MXene. InfoMat. https://doi.org/10.1002/inf2.12328
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.