Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reference Values of Body Composition Obtained by Dual Energy X‐Ray Absorptiometry in Preterm and Term Neonates

Rigo, Jacques, Nyamugabo, Kindja, Picaud, Jean Charle, Gerard, Paul, Pieltain, Catherine, De Curtis, Mario · 1998 · Journal of Pediatric Gastroenterology and Nutrition

Abstract

Background: As previously reported, dual‐energy x‐ray absorptiometry provides reliable and accurate values for bone mineralization in piglets and infants, but overestimates fat content in small infants. The purpose of the current study was to determine an appropriate equation of correction for at mass measurement and to establish reference values of body composition of preterm and term neonates. Methods: Fat mass and chemical whole‐body fat content were evaluated by dual‐energy x‐ray absorptiometry in eight piglets with a body weight between 1408 and 5151 g. The results were combined with previous data obtained in 13 piglets, and two correction equations were determined according to fat mass content. Close to birth, 106 healthy appropriate‐for‐gestational‐age preterm and term infants were scanned by dual‐energy x‐ray absorptiometry to determine bone mineral content, bone area, and fat mass. Fat mass content determined by dual‐energy x‐ray absorptiometry was corrected using the equations obtained in piglets after which lean body mass was recalculated. Results: Multivariate analysis showed that dual‐energy x‐ray absorptiometry body weight was the best predictor of bone mineral content (r2= 0.94), bone area (r2 = 0.95), lean body mass(r2 = 0.98), and fat mass (r2 = 0.84). Gender was an additional significant independent variable for fat mass and lean body mass. Body weight related curves of percentiles for bone mineral content, bone area, fat mass, and lean body mass, were constructed. In vivo dual‐energy x‐ray absorptiometry values of fat mass and calcium content estimated from bone mineral content were in accordance with previously reported whole‐body carcass reference values in preterm and term neonates. Conclusion: Normative data of dual‐energy x‐ray absorptiometry body composition for healthy preterm and term infants are provided and can therefore be used in research and in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/j.1536-4801.1998.tb01132.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Rigo, J., Nyamugabo, K., Picaud, J. C., Gerard, P., Pieltain, C., & De Curtis, M.
Venue
Journal of Pediatric Gastroenterology and Nutrition
Publisher
Wiley
Published
1998-08
Volume
27
Issue
2
Pages
184-190
ISSN
  • 0277-2116 (ISSN-L)
  • 1536-4801
OpenAlex
W1969649837
Cited by
184
References
1
FWCI
3.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reference Values of Body Composition Obtained by Dual Energy X‐Ray Absorptiometry in Preterm and Term Neonates. https://app.cochat.ai/papers/10.1002/j.1536-4801.1998.tb01132.x
The paper
Rigo, J., Nyamugabo, K., Picaud, J. C., Gerard, P., Pieltain, C., & De Curtis, M. (1998). Reference Values of Body Composition Obtained by Dual Energy X‐Ray Absorptiometry in Preterm and Term Neonates. Journal of Pediatric Gastroenterology and Nutrition. https://doi.org/10.1002/j.1536-4801.1998.tb01132.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.