Confocal Multimode Resonator for Millimeter Through Optical Wavelength Masers
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Multimode resonators of high quality factor will very likely play a significant role in the development of devices, such as the maser, which operate in the millimeter through optical wavelength range. It has been suggested that a plane-parallel Fabry-Perot interferometer could act as a suitable resonator. In this paper a resonator consisting of two identical concave spherical reflectors, separated by any distance up to twice their common radius of curvature, is considered. Mode patterns and diffraction losses for the low-loss modes of such a resonator are obtained analytically, using an approximate method which was suggested by W. D. Lewis. The results show that the diffraction losses are generally considerably lower for the curved surfaces than for the plane surfaces. Diffraction losses and mode volume are a minimum when the reflector spacing equals the common radius of curvature of the reflectors. For this case the resonator may be termed confocal. A further property of the concave spherical resonator is that the optical alignment is not extremely critical.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stimulated Optical Radiation in Ruby
MAIMAN, T. H. (1960) · Nature · doi:10.1038/187493a0 · Cited by 5,121
Prolate Spheroidal Wave Functions, Fourier Analysis and Uncertainty - I
Slepian, D., & Pollak, H. O. (1961) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1961.tb03976.x · Cited by 2,492
Schawlow, A. L., & Townes, C. H. (1958) · Physical Review · doi:10.1103/physrev.112.1940 · Cited by 2,354
L.R. (1957) · Nuclear Physics · doi:10.1016/0029-5582(87)90087-3 · Cited by 673
Optical properties of thin films
Heavens, O. S. (1960) · Reports on Progress in Physics · doi:10.1088/0034-4885/23/1/301 · Cited by 514
Cited by
Kogelnik, H., & Li, T. (1966) · Applied Optics · doi:10.1364/ao.5.001550 · Cited by 2,904
Parametric Interaction of Focused Gaussian Light Beams
Boyd, G. D., & Kleinman, D. A. (1968) · Journal of Applied Physics · doi:10.1063/1.1656831 · Cited by 1,694
Self-citationLens-System Diffraction Integral Written in Terms of Matrix Optics*
Collins, S. A. (1970) · Journal of the Optical Society of America · doi:10.1364/josa.60.001168 · Cited by 1,384
Hollow Metallic and Dielectric Waveguides for Long Distance Optical Transmission and Lasers
Marcatili, E. A. J., & Schmeltzer, R. A. (1964) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1964.tb04108.x · Cited by 1,381
Kogelnik, H., & Li, T. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.5119 · Cited by 1,149
Metadata
- Authors
- Boyd, G. D., & Gordon, J. P.
- Venue
- Bell System Technical Journal
- Published
- 1961-03
- Volume
- 40
- Issue
- 2
- Pages
- 489-508
- ISSN
- 0005-8580 (ISSN-L)
- OpenAlex
- W2098682104
- Cited by
- 883
- References
- 5
- FWCI
- 96.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.