CoChat

Effect of Interrupted Lens Wear on Compensation for a Minus Lens in Tree Shrews

Adam W. Shaikh, John T. Siegwart, Thomas T. Norton · 1999 · Optometry and Vision Science
Cited by 143

The DOI matches its OpenAlex record.

Abstract

BACKGROUND: When a young animal wears a monocular minus (concave) lens that shifts the focal plane away from the cornea, the vitreous chamber elongates over a period of days, shifting the retinal location to compensate for the altered focal plane. We examined the effect of removing the lens for a portion of each day on the amount of compensation in tree shrews. METHODS: Starting 24 days after natural eye opening, juvenile tree shrews wore a goggle frame that held a -5 D lens in front of one eye, with an open frame around the fellow control eye. The goggle was removed for 0, 0.5, 1, 2, or 7 h each day (N = 5, 5, 5, 5, and 3 animals per group, respectively), starting 0.5 h after the start of each 14 h light-on period. After 21 days of treatment, measures were made of the cycloplegic refractive state (streak retinoscopy) and the ocular component dimensions (A-scan ultrasound). Normal animals that experienced 14 h each day with no lens (N = 3) were also examined. RESULTS: The treated eyes of the 0 h group developed full refractive compensation for the lens (treated eye - control eye, mean +/- SEM = -5.8+/-1.1 D) and had increased vitreous chamber depth (0.13+/-0.02 mm) and axial length (0.12+/-0.02 mm) relative to the untreated control eye. The groups in which the lens was removed for 0.5 and 1 h each day showed partial compensation for the -5 D lens, both in refractive state (-4.2+/-0.4 D; -2.9+/-1.6 D) and in vitreous chamber depth (0.12+/-0.02 mm; 0.09+/-0.02 mm). The 2, 7, and 14 h (normal) groups showed no significant refractive or axial compensation. In the 0.5 and 1 h groups, A-scan ultrasound showed a thinning of the region between the front of the retina and back of the sclera. CONCLUSIONS: The eyes of tree shrews can tolerate altered monocular visual stimulation produced by a minus lens worn for 12 h of a 14-h light cycle without developing an induced myopia. However, when the lens is worn more than 12 of 14 h each day, compensation appears to increase linearly with decreased lens-off time. If the eyes of human children respond similarly to defocus from near work or other sources, it would seem that the defocus must be present almost all the time to induce myopia. If defocus contributes to human myopia through a compensation mechanism, then an increase in the amount of time that focused images are present should reduce myopic progression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1002/j.1538-9235.1999.tb05401.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Shaikh, A. W., Siegwart, J. T., & Norton, T. T.
Venue
Optometry and Vision Science
Publisher
Lippincott Williams & Wilkins
Published
1999-05-01
Volume
76
Issue
5
Pages
308-315
ISSN
1040-5488 (ISSN-L)
OpenAlex
W1982073366
Cited by
143
References
0
FWCI
2.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Interrupted Lens Wear on Compensation for a Minus Lens in Tree Shrews. https://app.cochat.ai/papers/10.1002/j.1538-9235.1999.tb05401.x
The paper
Shaikh, A. W., Siegwart, J. T., & Norton, T. T. (1999). Effect of Interrupted Lens Wear on Compensation for a Minus Lens in Tree Shrews. Optometry and Vision Science. https://doi.org/10.1002/j.1538-9235.1999.tb05401.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.