The DOI matches its OpenAlex record.
Visual Acuity as a Function of Zernike Mode and Level of Root Mean Square Error
Abstract
BACKGROUND: The coefficients of normalized Zernike expansion are orthogonal and reflect the relative contribution of each mode to the total root mean square (RMS) wavefront error. The relationship between the level of RMS wavefront error within a mode and its effect on visual performance is unknown. PURPOSE: To determine for various levels of RMS wavefront error how each mode of the normalized Zernike expansion for the second, third, and fourth orders affect high- and low-contrast acuity. METHODS: Three healthy optimally corrected cyclopleged subjects read aberrated and unaberrated high- and low-contrast logarithm of the minimum angle of resolution acuity charts monocularly through a 3-mm artificial pupil. Acuity was defined by the total number of letters read correctly up to the fifth miss. Aberrated and unaberrated charts were generated using a program called CTView. Six levels of RMS wavefront error were used (0.00, 0.05, 0.10, 0.15, 0.20, and 0.25 microm). Each level of RMS error was loaded into each mode of the second, third, and fourth radial orders individually for a total of 72 charts. Data were normalized by subject, and the normalized data were averaged across subjects. RESULTS: Across modes and within each mode as the level of RMS wavefront error increased above 0.05 microm of RMS wavefront error, visual acuity decreased in a linear fashion. Slopes of the linear fits varied depending on the mode. Modes near the center of the Zernike pyramid had steeper slopes than those near the edge. CONCLUSIONS: Increasing the RMS error within any single mode of the normalized Zernike expansion decreases visual acuity in a linear fashion. The slope of the best fitting linear equation varies with Zernike mode. Slopes near the center of the Zernike pyramid are steeper than those near the edge. Although the normalized Zernike expansion parcels RMS error orthogonally, the resulting effects on visual performance as measured by visual acuity are not orthogonal. New metrics of the combined effects of the optical and the neural transfer functions that are predictive of visual performance need to be developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chicco, D., Warrens, M. J., & Jurman, G. (2021) · PeerJ Computer Science · doi:10.7717/peerj-cs.623 · Cited by 5,380
Accuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Self-citationMetrics of optical quality derived from wave aberrations predict visual performance
Marsack, J. D., Thibos, L. N., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.8 · Cited by 341
Self-citationPredicting subjective judgment of best focus with objective image quality metrics
Cheng, X., Bradley, A., & Thibos, L. N. (2004) · Journal of Vision · doi:10.1167/4.4.7 · Cited by 255
Legras, R., Benard, Y., & Lopez-Gil, N. (2012) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.10.032 · Cited by 46
Metadata
- Authors
- Applegate, R. A., Ballentine, C. S., Gross, H., Sarver, E. J., & SARVER, C. A.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2003-02-01
- Volume
- 80
- Issue
- 2
- Pages
- 97-105
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2111676515
- Cited by
- 245
- References
- 0
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visual Acuity as a Function of Zernike Mode and Level of Root Mean Square Error. https://app.cochat.ai/papers/10.1002/j.1538-9235.2003.tb01600.x
- The paper
- Applegate, R. A., Ballentine, C. S., Gross, H., Sarver, E. J., & SARVER, C. A. (2003). Visual Acuity as a Function of Zernike Mode and Level of Root Mean Square Error. Optometry and Vision Science. https://doi.org/10.1002/j.1538-9235.2003.tb01600.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.