Clinical Evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K Autorefractor
The DOI matches its OpenAlex record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
PURPOSE: A clinical evaluation of the Shin-Nippon NVision-K 5001 (also branded as the Grand Seiko WR-5100K) autorefractor (Japan) was performed to examine validity and repeatability compared with subjective refraction and Javal-Schiotz keratometry. METHODS: Measurements of refractive error were performed on 198 eyes of 99 subjects (aged 23.2 +/- 7.4 years) subjectively (noncycloplegic) by one masked optometrist and objectively with the NVision-K autorefractor by a second optometrist. Keratometry measurements using the NVision-K were compared with the Javal-Schiotz keratometer. Intrasession repeatability of the NVision-K was also assessed on all 99 subjects together with intersession repeatability on a separate occasion separated by 7 to 14 days. RESULTS: Refractive error as measured by the NVision-K was found to be similar (p = 0.67) to subjective refraction (difference, 0.14 +/- 0.35 D). It was both accurate and repeatable over a wide prescription range (-8.25 to +7.25 D). Keratometry as measured by the NVision-K was found to be similar (p > 0.50) to the Javal-Schiotz technique in both the horizontal and vertical meridians (horizontal: difference, 0.02 +/- 0.09 mm; vertical: difference, 0.01 +/- 0.14 mm). There was minimal bias, and the results were repeatable (horizontal: intersession difference, 0.00 +/- 0.09 mm; vertical: intersession difference, -0.01 +/- 0.12 mm). CONCLUSION: The open-view arrangement of the Shin-Nippon NVision-K 5001 facilitates the measurement of static refractive error and the accommodative response to real-world stimuli. Coupled with its accuracy, repeatability, and capability to measure corneal curvature, it is a valuable addition to objective instrumentation currently available to the optometrist and researcher.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Thibos, L. N., WHEELER, W., & Horner, D. G. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04707.x · Cited by 1,238
Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults
Mallen, E. A. H., Wolffsohn, J. S., Gilmartin, B., & Tsujimura, S. (2001) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(00)00049-1 · Cited by 217
Self-citationClinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children
Chat, S. W., & Edwards, M. H. (2001) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(00)00048-x · Cited by 149
Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor
Wolffsohn, J. S., Gilmartin, B., Mallen, E. A. H., & Tsujimura, S. (2001) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2001.00586.x · Cited by 81
Self-citationClinical evaluation of a range of autorefractors
McCaghrey, G. E., & Matthews, F. E. (1993) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1993.tb00441.x · Cited by 44
Evaluation of two infrared autorefractors in pseudophakia
Reeves, B. C., Hill, A. R., Carter, S. C., & Sparrow, J. M. (1992) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(92)90168-v · Cited by 8
Cited by
Prediction of Juvenile-Onset Myopia
Zadnik, K., Sinnott, L. T., Cotter, S. A., Jones-Jordan, L. A., Kleinstein, R. N., Manny, R. E., Twelker, J. D., & Mutti, D. O. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2015.0471 · Cited by 366
Peripheral refraction along the horizontal and vertical visual fields in myopia
Atchison, D. A., Pritchard, N., & Schmid, K. L. (2006) · Vision Research · doi:10.1016/j.visres.2005.10.023 · Cited by 285
Relative Peripheral Refractive Error and the Risk of Onset and Progression of Myopia in Children
Mutti, D. O., Sinnott, L. T., Mitchell, G. L., Jones-Jordan, L. A., Moeschberger, M. L., Cotter, S. A., Kleinstein, R. N., Manny, R. E., Twelker, J. D., & Zadnik, K. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4826 · Cited by 217
McCullough, S. J., O’Donoghue, L., & Saunders, K. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0146332 · Cited by 147
Metadata
- Authors
- Davies, L. N., Mallen, E. A. H., Wolffsohn, J. S., & GILMARTIN, A. B.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2003-04-01
- Volume
- 80
- Issue
- 4
- Pages
- 320-324
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W1980515521
- Cited by
- 198
- References
- 8
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.