Cited by 156Arsenic contamination and mitigationCoagulation and Flocculation StudiesWater Treatment and Disinfection

The DOI matches its Crossref record.

Soluble arsenic removal at water treatment plants

McNeill, Laurie S., Edwards, Marc·1995·Journal AWWA

Abstract

Conventional treatment steps can be extremely effective at removing arsenic. Arsenic “profiles” were obtained from full‐scale conventional treatment (coagulation, Fe–Mn oxidation, or softening) plants, facilitating testing of theories regarding arsenic removal. Soluble As(V) removal efficiency was controlled primarily by pH during coagulation, by Fe+2 oxidation and Fe(OH)3 precipitation during Fe–Mn oxidation, and by Mg(OH)2 formation during softening. Insignificant soluble As(V) removal occurred during calcite precipitation at softening plants or during Mn+2 oxidation–precipitation at Fe–Mn oxidation plants. The extent of soluble As(V) removal during coagulation and softening treatments was lower than expected. Somewhat surprisingly, during coagulation As(V) removal efficiencies were limited by particulate aluminum formation and removal, because much of the added coagulant was not removed by 0.45‐μm‐pore‐size filters. At one utility, reducing the coagulation pH from 7.4 to 6.8 (at constant alum dose) improved removal of particulate aluminum, thereby enhancing soluble As(V) removal during treatment.

Overview

Integrity signals

Registry

Crossref · 10.1002/j.1551-8833.1995.tb06346.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 7

  1. 1992, Water Industry Data Base: Utility Profiles
  2. 10.1016/0039-9140(83)80084-8 · DOI
  3. Clifford D.;Ceber L.; &Chow S.Arsenic(III)/As(V) Separation by Chloride‐Form Ion‐Exchange Resins.Proc. 1983 AWWA WQTC Norfolk Va..
  4. 10.1002/j.1551-8833.1994.tb06247.x · DOI
  5. Scott K.N.et al.Arsenic Removal Using Elevated Dosages of Ferric Chloride and Alum at a Full‐Scale Conventional Treatment Plant.Proc. 1994 AWWA WQTC San Francisco Calif..
  6. 10.1002/j.1551-8833.1978.tb04198.x · DOI
  7. McNeill L., 1994, Critical Issues in Water and Wastewater Treatment: Proceedings of the 1994 ASCE National Conference on Environmental Engineering

Cited by

Sorted by citations

Metadata

Authors
McNeill, L. S., & Edwards, M.
Venue
Journal AWWA
Publisher
Wiley
Published
1995-04
Volume
87
Issue
4
Pages
105-113
ISSN
  • 0003-150X (ISSN-L)
  • 1551-8833
OpenAlex
W1582173192
Cited by
156
References
0
Citations by year
2026: 2 · 2024: 1 · 2023: 3 · 2022: 5 · 2021: 4 · 2020: 6 · 2019: 7 · 2018: 6 · 2017: 7 · 2016: 2 · 2015: 2 · 2014: 4 · 2013: 7 · 2012: 3
FWCI
4.83
Type
journal article
Language
en
Open access
closed
Locations
American Water Works Association (publishedVersion)
Funders
Cisco Systems
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Arsenic contamination and mitigation
  • Physical Sciences › Environmental Science › Water Science and Technology › Coagulation and Flocculation Studies
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
Keywords
arsenic removal, arsenate, drinking water treatment, coagulation, softening, pH, alum coagulant, calcite precipitation, manganese oxidation, iron hydroxide precipitation, aluminum particles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review