The DOI matches its Crossref record.
Arsenic removal by RO and NF membranes
Open accessAbstract
RO and tight NF membranes prove equally effective in removing As species over a wide range of operational conditions. Bench‐scale experiments were performed to assess the effectiveness of reverse osmosis (RO) and nanofiltration (NF) membranes in removing arsenic (As) from synthetic freshwater and source water. The authors examined the effects of operational conditions (applied pressure and feedwater temperature) and solution chemical composition (As oxidation state, pH, and presence of co‐occurring inorganic solutes). Both As(V) and As (III) were effectively removed from synthetic freshwater by RO and tight NF membranes over a wide range of operational conditions. The relatively large molecular weight (>125 g/mol) of the As species governed their separation behavior. Applied pressure had little effect on As removal, but an increase in feedwater temperature decreased As removal by a small percentage. Removals of As (III) and As(V) were comparable, with no significant preferential rejection of As(V) over As (III). Variations in solution pH from 4 to 8 also did not affect the removal of As species by the membranes tested, despite changes in the speciation and charge of As(V). Co‐occurring inorganic solutes had only a slight effect on As removal. Removal of As from source water was comparable to that obtained with synthetic freshwater, despite the presence of turbidity, natural organic matter, and a variety of co‐occurring solutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Arsenic contamination, consequences and remediation techniques: A review
Singh, R., Singh, S., Parihar, P., Singh, V. P., & Prasad, S. M. (2015) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2014.10.009 · Cited by 1,099
Water purification by membranes: The role of polymer science
Geise, G. M., Lee, H., Miller, D. J., Freeman, B. D., McGrath, J. E., & Paul, D. R. (2010) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22037 · Cited by 972
Arsenic toxicity, health hazards and removal techniques from water: an overview
Choong, T. S. Y., Chuah, T. G., Robiah, Y., Gregory Koay, F. L., & Azni, I. (2007) · Desalination · doi:10.1016/j.desal.2007.01.015 · Cited by 912
Drawbacks of applying nanofiltration and how to avoid them: A review
Van der Bruggen, B., Mänttäri, M., & Nyström, M. (2008) · Separation and Purification Technology · doi:10.1016/j.seppur.2008.05.010 · Cited by 878
Fundamental water and salt transport properties of polymeric materials
Geise, G. M., Paul, D. R., & Freeman, B. D. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.07.001 · Cited by 783
Metadata
- Authors
- Waypa, J. J., Elimelech, M., & Hering, J. G.
- Venue
- Journal AWWA
- Publisher
- Wiley
- Published
- 1997-10
- Volume
- 89
- Issue
- 10
- Pages
- 102-114
- ISSN
- 0003-150X (ISSN-L)
- 1551-8833
- OpenAlex
- W1511022383
- Cited by
- 170
- References
- 0
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arsenic removal by RO and NF membranes. https://app.cochat.ai/papers/10.1002/j.1551-8833.1997.tb08309.x
- The paper
- Waypa, J. J., Elimelech, M., & Hering, J. G. (1997). Arsenic removal by RO and NF membranes. Journal AWWA. https://doi.org/10.1002/j.1551-8833.1997.tb08309.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.