Arsenic removal from drinking water using the coagulation/microfiltratin process
The DOI matches its Crossref record.
Abstract
The US Environmental Protection Agency (USEPA) has promulgated the Arsenic Rule and lowered the arsenic maximum contaminant level from 50 μg/L to 10 μg/L. Many water systems will be faced with implementing a treatment technology for removing arsenic to meet the compliance deadline of January 23, 2006. Coagulation/microfiltration (C/MF) technology has been recognized by the USEPA as an emerging technology for the removal of arsenic from drinking water. During the past five years, the authors have implemented several pilot tests to evaluate the performance of the C/MF process. This pilot testing has shown that C/MF is a robust and cost‐effective technology for arsenic treatment. This article presents a summary of the process concepts, chemistry, and design considerations for the use of C/MF technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2014) · Analytical Chemistry · doi:10.1021/ac500508t · Cited by 2,144
Arsenic contamination, consequences and remediation techniques: A review
Singh, R., Singh, S., Parihar, P., Singh, V. P., & Prasad, S. M. (2015) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2014.10.009 · Cited by 1,099
Coagulation and Flocculation in Water and Wastewater Treatment
Bratby, J. (2016) · Water Intelligence Online · doi:10.2166/9781780407500 · Cited by 1,083
Arsenic toxicity, health hazards and removal techniques from water: an overview
Choong, T. S. Y., Chuah, T. G., Robiah, Y., Gregory Koay, F. L., & Azni, I. (2007) · Desalination · doi:10.1016/j.desal.2007.01.015 · Cited by 912
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2005) · Analytical Chemistry · doi:10.1021/ac058022x · Cited by 363
Metadata
- Authors
- Chwirka, J. D., Colvin, C., Gomez, J. D., & Mueller, P. A.
- Venue
- Journal AWWA
- Publisher
- Wiley
- Published
- 2004-03
- Volume
- 96
- Issue
- 3
- Pages
- 106-114
- ISSN
- 0003-150X (ISSN-L)
- 1551-8833
- OpenAlex
- W1492996808
- Cited by
- 61
- References
- 0
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arsenic removal from drinking water using the coagulation/microfiltratin process. https://app.cochat.ai/papers/10.1002/j.1551-8833.2004.tb10578.x
- The paper
- Chwirka, J. D., Colvin, C., Gomez, J. D., & Mueller, P. A. (2004). Arsenic removal from drinking water using the coagulation/microfiltratin process. Journal AWWA. https://doi.org/10.1002/j.1551-8833.2004.tb10578.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.