CoChat

Patient Self‐Reporting of Compliance Does Not Correspond with Electronic Monitoring: An Evaluation Using Isosorbide Dinitrate as a Model Drug

Open access
Straka, Robert J., Fish, Jeffrey T., Benson, Steven R., Suh, J. Thomas · 1997 · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
Cited by 133

The DOI matches its Crossref record.

Abstract

Study Objective . To assess the accuracy of patient‐kept diaries relative to electronic monitoring of compliance with isosorbide dinitrate prescribed 3 times/day for ischemic heart disease. Design . Unblinded, prospective, three‐phase study. Methods . Patients with coronary artery disease prescribed isosorbide dinitrate 3 times/day were asked to record the time of administration of each dose in a pocket diary while being monitored for compliance with a computerized Medication‐Event Monitoring System (MEMS‐4) vial that electronically recorded the date and time the vial was opened. Results . Sixty‐eight stable outpatients with documented coronary artery disease who were prescribed isosorbide dinitrate 3 times/day were evaluated. Based on a prospectively chosen definition including a nitrate‐free period, the mean (± SD) overall compliance rates were 71% (± 30) versus 55% (± 32) for the patient‐kept diaries and the MEMS vials respectively (p=0.001). The concordance between patient‐kept diaries and MEMS data indicate that 67% of patients overestimate their compliance when using a self‐recording tool. An average of 30% of diary entries were in error compared with the MEMS vial recordings. Conclusions . Patient‐kept diaries statistically overestimate actual compliance relative to that determined by MEMS devices. Given the prevalence of the use of diaries as the predominant tool on which researchers depend to document compliance with study drugs, our findings suggest that this practice should be reevaluated specifically when the time of the dose and documentation of administration are critical to qualifying the outcome of drug therapy. Such is the case with isosorbide dinitrate use in patients with ischemic heart disease. Furthermore, the overall poor compliance documented in this study suggests that the utility of isosorbide dinitrate prescribed 3 times/day be reevaluated as a clinically effective antianginal drug.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/j.1875-9114.1997.tb03685.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 133

Metadata

Authors
Straka, R. J., Fish, J. T., Benson, S. R., & Suh, J. T.
Venue
Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
Publisher
Wiley
Published
1997-01-02
Volume
17
Issue
1
Pages
126-132
ISSN
  • 0277-0008 (ISSN-L)
  • 1875-9114
OpenAlex
W2157455042
Cited by
133
References
0
FWCI
7.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patient Self‐Reporting of Compliance Does Not Correspond with Electronic Monitoring: An Evaluation Using Isosorbide Dinitrate as a Model Drug. https://app.cochat.ai/papers/10.1002/j.1875-9114.1997.tb03685.x
The paper
Straka, R. J., Fish, J. T., Benson, S. R., & Suh, J. T. (1997). Patient Self‐Reporting of Compliance Does Not Correspond with Electronic Monitoring: An Evaluation Using Isosorbide Dinitrate as a Model Drug. Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy. https://doi.org/10.1002/j.1875-9114.1997.tb03685.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.