CoChat

RMieS‐EMSC correction for infrared spectra of biological cells: Extension using full Mie theory and GPU computing

Open access
Bassan, Paul, Kohler, Achim, Martens, Harald, Lee, Joe, Jackson, Edward, Lockyer, Nicholas, Dumas, Paul, Brown, Michael, Clarke, Noel, Gardner, Peter · 2010 · Journal of Biophotonics
Cited by 134

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In the field of biomedical infrared spectroscopy it is often desirable to obtain spectra at the cellular level. Samples consisting of isolated single biological cells are particularly unsuited to such analysis since cells are strong scatterers of infrared radiation. Thus measured spectra consist of an absorption component often highly distorted by scattering effects. It is now known that the predominant contribution to the scattering is Resonant Mie Scattering (RMieS) and recently we have shown that this can be corrected for, using an iterative algorithm based on Extended Multiplicative Signal Correction (EMSC) and a Mie approximation formula. Here we present an iterative algorithm that applies full Mie scattering theory. In order to avoid noise accumulation in the iterative algorithm a curve‐fitting step is implemented on the new reference spectrum. The new algorithm increases the computational time when run on an equivalent processor. Therefore parallel processing by a Graphics Processing Unit (GPU) was employed to reduce computation time. The optimised RMieS‐EMSC algorithm is applied to an IR spectroscopy data set of cultured single isolated prostate cancer (PC‐3) cells, where it is shown that spectral distortions from RMieS are removed. (© 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbio.201000036

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 134

Metadata

Authors
Bassan, P., Kohler, A., Martens, H., Lee, J., Jackson, E., Lockyer, N., Dumas, P., Brown, M., Clarke, N., & Gardner, P.
Venue
Journal of Biophotonics
Publisher
Wiley
Published
2010-07-19
Volume
3
Issue
8-9
Pages
609-620
ISSN
  • 1864-063X (ISSN-L)
  • 1864-0648
OpenAlex
W2043197681
Cited by
134
References
2
FWCI
6.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: RMieS‐EMSC correction for infrared spectra of biological cells: Extension using full Mie theory and GPU computing. https://app.cochat.ai/papers/10.1002/jbio.201000036
The paper
Bassan, P., Kohler, A., Martens, H., Lee, J., Jackson, E., Lockyer, N., Dumas, P., Brown, M., Clarke, N., & Gardner, P. (2010). RMieS‐EMSC correction for infrared spectra of biological cells: Extension using full Mie theory and GPU computing. Journal of Biophotonics. https://doi.org/10.1002/jbio.201000036

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.