The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Engineering protein and cell adhesivity using PEO‐terminated triblock polymers
Abstract
Previous studies on customizing cell culture environments have utilized a variety of microfabrication‐based tools to control the spatial localization of adhesive proteins and subsequently mammalian cells. Others have used various methods to immobilize nonadhesive PEO‐based polymers on surfaces to inhibit protein absorption and cell adhesion. In this study, we report the application of a well‐characterized, commercially available, PEO‐terminated triblock polymer (Pluronic™ F108) to create micropatterned nonadhesive domains on a variety of biomaterials that deter cell adhesion for up to 4 weeks in culture. The Pluronic can be applied using microfluidic tools or photolithographic techniques, and can be adsorbed to a variety of common surfaces including tissue culture polystyrene, methylated glass, silicone, and polylactic‐co‐glycolic acid. The effectiveness of the Pluronic in inhibiting cell adhesion in the presence of collagen I is also quantified. Finally, these patterning techniques are generalized to control tissue organization on a variety of common biomaterials. This simple method for micropatterning PEO and, therefore, proteins and cells should prove useful as a tool for biomolecular surface engineering. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 126–134, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Self-citation
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,558
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437
Self-citationSurface engineering approaches to micropattern surfaces for cell-based assays
Falconnet, D., Csucs, G., Michelle Grandin, H., & Textor, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.024 · Cited by 944
Inkjet printing for high-throughput cell patterning
Roth, E. A., Xu, T., Das, M., Gregory, C., Hickman, J. J., & Boland, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.052 · Cited by 714
Metadata
- Authors
- Liu, V. A., Jastromb, W. E., & Bhatia, S. N.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-01-23
- Volume
- 60
- Issue
- 1
- Pages
- 126-134
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2059466663
- Cited by
- 206
- References
- 1
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.