The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Degradation characteristics of α and β tri‐calcium‐phosphate (TCP) in minipigs
Abstract
In seven Goettingen minipigs 3.5–4.7‐ml cancellous bone defects were created in the area of the tibial head on both sides. The defects were filled with α‐TCP or β‐TCP (tricalciumphosphate). ITI implants (Straumann, Freiburg, Germany) of 3.2 × 12‐mm length were inserted into the underlying ceramic substitutes. Two additional pigs were used as control. Within the periods of observation (4, 16, 20, 28, 46, 68, and 86 weeks) fluorescent dyes were applied. Nondecalcified thin‐sliced sections were examined by means of light and fluorescence microscopy. In addition microangiography and microradiography were performed. Bony regeneration occurred basally and on the sides of the defect according the angiogenetic reossification pattern. Resorption was due to a hydrolytic and cellular degradation process. After 46 weeks histomorphological evaluation showed an incomplete osseointegration of the simultaneously implanted dental implants. The bone contact surface ratio was lower than 25%. After 86 weeks 95–97% of both α‐ and β‐TCP were resorbed. Ceramic residuals stayed within the newly formed trabeculae thus resisting further degradation until remodeling occurred. Both α‐ and β‐TCP show a comparable degradation process. At the 86‐week postoperative point only small residuals of the ceramic can be found. These residuals stay within the newly formed trabeculae, which show a functional orientation. In comparison control defects showed only sparse reossification. The β‐TCP material shows an accelerated degradation mode and has an optimal reactivity with the surrounding tissues. According to the results of this animal experiment both materials can be classified as bone‐rebuilding materials. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res (Appl Biomater) 63: 115–121, 2002; DOI 10.1002/jbm.10084
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
The Critical Size Defect as an Experimental Model for Craniomandibulofacial Nonunions
SCHMITZ, J. P., & HOLLINGER, J. O. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198604000-00036 · Cited by 1,317
Cited by
Additive manufacturing of biomaterials
Bose, S., Ke, D., Sahasrabudhe, H., & Bandyopadhyay, A. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.08.003 · Cited by 738
Bone Grafts and Bone Graft Substitutes in Orthopaedic Trauma Surgery: A Critical Analysis
De Long, W. G., Einhorn, T. A., Koval, K., McKee, M., Smith, W., Sanders, R., & Watson, T. (2007) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.f.00465 · Cited by 570
α-Tricalcium phosphate: Synthesis, properties and biomedical applications
Carrodeguas, R. G., & De Aza, S. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.019 · Cited by 534
Polymeric composites for powder-based additive manufacturing: Materials and applications
Yuan, S., Shen, F., Chua, C. K., & Zhou, K. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.11.001 · Cited by 525
Improving biocompatibility for next generation of metallic implants
Bandyopadhyay, A., Mitra, I., Goodman, S. B., Kumar, M., & Bose, S. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101053 · Cited by 463
Metadata
- Authors
- Wiltfang, J., Merten, H. A., Schlegel, K. A., Schultze‐Mosgau, S., Kloss, F. R., Rupprecht, S., & Kessler, P.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 63
- Issue
- 2
- Pages
- 115-121
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2101278481
- Cited by
- 255
- References
- 2
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.