The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrically communicating three‐dimensional cardiac tissue mimic fabricated by layered cultured cardiomyocyte sheets
Abstract
Recent progress in stem cell biology is likely to provide implantable sources of human cardiomyocytes in the near future. This possibility has encouraged cardiac tissue engineering. To construct heart‐like tissue, we have exploited the capabilities of novel cell culture surfaces grafted with a temperature‐responsive polymer, poly(N‐isopropylacrylamide) (PIPAAm), to produce intact viable monolayer cell sheets simply by reducing culture temperature. Cultured chick embryonic cardiomyocyte sheets detached from PIPAAm‐grafted surfaces were layered into tissue‐like laminate stacks using hydrophilic support and transfer membranes. The layered cell sheets rapidly adhered to each other, establishing cell‐to‐cell connections characteristic of heart tissue, including desmosomes and intercalated disks. Bilayer cell sheets pulsed spontaneously and synchronously, altering their characteristic pulsing frequency with applied electric stimulation transmitted across the sheets. These results demonstrate that electrically communicative three‐dimensional cardiac constructs can be achieved by stacking monolayer cardiomyocyte sheets. Cardiac tissue engineering based on this technology will facilitate new in vitro heart models and may prove useful for in vivo cardiovascular tissue repair. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 110–117, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Cited by
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Shimizu, T., Yamato, M., Isoi, Y., Akutsu, T., Setomaru, T., Abe, K., Kikuchi, A., Umezu, M., & Okano, T. (2002) · Circulation Research · doi:10.1161/hh0302.105722 · Cited by 956
Self-citationSmart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Bishop, E. S., Mostafa, S., Pakvasa, M., Luu, H. H., Lee, M. J., Wolf, J. M., Ameer, G. A., He, T.-C., & Reid, R. R. (2017) · Genes & Diseases · doi:10.1016/j.gendis.2017.10.002 · Cited by 683
Cell sheet engineering for myocardial tissue reconstruction
Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00110-8 · Cited by 673
Self-citation
Metadata
- Authors
- Shimizu, T., Yamato, M., Akutsu, T., Shibata, T., Isoi, Y., Kikuchi, A., Umezu, M., & Okano, T.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2002-01-15
- Volume
- 60
- Issue
- 1
- Pages
- 110-117
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1978055200
- Cited by
- 202
- References
- 1
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.