Blood–materials interactions: The minimum interfacial free energy and the optimum polar/apolar ratio hypotheses
The DOI matches its Crossref record.
Abstract
Numerous hypotheses exist to explain observed blood–materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer‐coated tubes; centrifugal force platelet adhesion on polymer‐coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer‐coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood–materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parameters influencing the stealthiness of colloidal drug delivery systems
Vonarbourg, A., Passirani, C., Saulnier, P., & Benoit, J.-P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.039 · Cited by 740
Blood compatibility of polyethylene oxide surfaces
LEE, J., LEE, H., & ANDRADE, J. (1995) · Progress in Polymer Science · doi:10.1016/0079-6700(95)00011-4 · Cited by 703
Self-citationLong circulating microparticulate drug carriers
Stolnik, S., Illum, L., & Davis, S. S. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00025-3 · Cited by 700
Interaction of Different Types of Cells on Polymer Surfaces with Wettability Gradient
Lee, J. H., Khang, G., Lee, J. W., & Lee, H. B. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5688 · Cited by 482
Protein‐resistant surfaces prepared by PEO‐containing block copolymer surfactants
Lee, J. H., Kopecek, J., & Andrade, J. D. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230306 · Cited by 436
Self-citation
Metadata
- Authors
- Coleman, D. L., Gregonis, D. E., & Andrade, J. D.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1982-07
- Volume
- 16
- Issue
- 4
- Pages
- 381-398
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1997483646
- Cited by
- 141
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood–materials interactions: The minimum interfacial free energy and the optimum polar/apolar ratio hypotheses. https://app.cochat.ai/papers/10.1002/jbm.820160407
- The paper
- Coleman, D. L., Gregonis, D. E., & Andrade, J. D. (1982). Blood–materials interactions: The minimum interfacial free energy and the optimum polar/apolar ratio hypotheses. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820160407
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.