Effect of pore size on the peel strength of attachment of fibrous tissue to porous‐surfaced implants
Abstract
Twenty‐four rectangular metal plates were fabricated with surface regions in three different pore size ranges (5–20 μm, 20–50 μm, 50–200 μm). The plates were implanted into the dorsal subcutaneous tissue of 12 adult mongrel dogs for periods of 4, 8, 12, and 16 weeks. After animal sacrifice, the fibrous tissue which adhered to the porous‐surfaced regions of each plate was mechanically peeled off to give an indication of the strength of tissue attachment. The tissue was examined by both transmitted light and scanning electron microscopy. At each time period, the tissue that contacted the porous regions was found to be collagenized fibroconnective tissue. The mechanical tests indicated an increasing strength of tissue attachment with increasing implantation time and pore size range. The largest pore size range of approximately 50–200 μm produced a mean peel strength of attachment of 27.5 g/mm at the 16‐week period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tough bonding of hydrogels to diverse non-porous surfaces
Yuk, H., Zhang, T., Lin, S., Parada, G. A., & Zhao, X. (2016) · Nature Materials · doi:10.1038/nmat4463 · Cited by 1,184
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Classification of biomaterials and their related complications in abdominal wall hernia surgery
Amid, P. K. (1997) · Hernia · doi:10.1007/bf02426382 · Cited by 751
Fatigue-resistant adhesion of hydrogels
Liu, J., Lin, S., Liu, X., Qin, Z., Yang, Y., Zang, J., & Zhao, X. (2020) · Nature Communications · doi:10.1038/s41467-020-14871-3 · Cited by 420
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
Metadata
- Authors
- Bobyn, J. D., Wilson, G. J., MacGregor, D. C., Pilliar, R. M., & Weatherly, G. C.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1982-09
- Volume
- 16
- Issue
- 5
- Pages
- 571-584
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2011301897
- Cited by
- 184
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of pore size on the peel strength of attachment of fibrous tissue to porous‐surfaced implants. https://app.cochat.ai/papers/10.1002/jbm.820160505
- The paper
- Bobyn, J. D., Wilson, G. J., MacGregor, D. C., Pilliar, R. M., & Weatherly, G. C. (1982). Effect of pore size on the peel strength of attachment of fibrous tissue to porous‐surfaced implants. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820160505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.