The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
A new glass‐ceramic for bone replacement: Evaluation of its bonding to bone tissue
Abstract
Glass powders (350 mesh) of the composition MgO, 4.6; CaO, 44.9; SiO, 34.2; PO, 16.3; CaF, 0.5 in weight ratio were compacted, heated to 1050°C at a rate of 5°C/ min and kept at 1050°C for 2 h. The resultant glass‐ceramic having oxyapatite, fluoroapatite, and wollastonite crystals showed high bending and compressive strengths of 157 and 1060 MPa, respectively. The biocompatibility and bonding ability of this new glass‐ceramic to the bone tissue was evaluated using rabbit tibial bones, and the failure load to break the bonding of several ceramics (the new glass‐ceramic, dense hydroxyapatite, 45S5 Bioglass, alumina‐ceramic) to bone tissues was measured. The new glass‐ceramic showed tight bonding to bone comparable with dense hydroxyapatite, and in 25 weeks its load was 70% of that of bone tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonding mechanisms at the interface of ceramic prosthetic materials
Hench, L. L., Splinter, R. J., Allen, W. C., & Greenlee, T. K. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050611 · Cited by 3,251
Low Friction Arthroplasty of the Hip
Charnley, J. (1979) · Springer eBooks · doi:10.1007/978-3-642-67013-8 · Cited by 927
Low Friction Arthroplasty of the Hip: Theory and Practice
Charnley, J. (1978) · Medical Entomology and Zoology · Cited by 718
The Mechanical Properties of Cortical Bone
REILLY, D. T., & BURSTEIN, A. H. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456050-00012 · Cited by 653
Scanning electron microscopy of primary membrane bone
BOYDE, A., & HOBDELL, M. H. (1969) · Cell and Tissue Research · doi:10.1007/bf00338800 · Cited by 107
Fixation of porous titanium implants in cortical bone enhanced by electrical stimulation
Colella, S. M., Miller, A. G., Stang, R. G., Stoebe, T. G., & Spengler, D. M. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150108 · Cited by 45
Cited by
Apatite formation on the surface of ceravital‐type glass‐ceramic in the body
Ohtsuki, C., Kushitani, H., Kokubo, T., Kotani, S., & Yamamuro, T. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251105 · Cited by 259
Self-citation
Metadata
- Authors
- Nakamura, T., Yamamuro, T., Higashi, S., Kokubo, T., & Itoo, S.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1985-07
- Volume
- 19
- Issue
- 6
- Pages
- 685-698
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2123204757
- Cited by
- 441
- References
- 6
- FWCI
- 9.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new glass‐ceramic for bone replacement: Evaluation of its bonding to bone tissue. https://app.cochat.ai/papers/10.1002/jbm.820190608
- The paper
- Nakamura, T., Yamamuro, T., Higashi, S., Kokubo, T., & Itoo, S. (1985). A new glass‐ceramic for bone replacement: Evaluation of its bonding to bone tissue. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820190608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.