The DOI matches its Crossref record.
Growth of bone marrow cells on porous ceramics in vitro
Abstract
Following the transplantation of bone marrow cells to extra‐osseous sites, bone formation occurs in those sites. This osteogenic potential of bone marrow cells might be utilized for filling defects in bone if they could be transported on porous ceramic materials. Before such an approach becomes feasible, it is important to know what happens to the cells in the presence of the ceramics that might be used. In order to investigate the interaction between bone marrow cells and ceramics, in vitro, a system for culturing bone marrow cells on ceramic materials has been developed. Bone marrow cells adhered well to the surface of calcium hydroxyapatite and tricalcium phosphate ceramics, and this was followed by the formation of fibrous tissue on and within the ceramics. These ceramics were compatible with bone marrow cells even in culture conditions in which there was a large surface area of ceramic interfacing with cells. The results support the proposal that calcium hydroxyapatite and tricalcium phosphate are appropriate as bone replacement materials. In contrast, calcium aluminate had an adverse effect on bone marrow cells when there was a high proportion of ceramic to culture medium. However, this effect was not present if the proportion of ceramic to culture medium was low. Therefore, a large amount of biodegradable porous calcium aluminate ceramic should not be used as an alternative to autogeneous bone grafting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
Itälä, A. I., Ylänen, H. O., Ekholm, C., Karlsson, K. H., & Aro, H. T. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1069 · Cited by 379
Metadata
- Authors
- Uchida, A., Nade, S., McCartney, E., & Ching, W.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1987-01
- Volume
- 21
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2000038919
- Cited by
- 233
- References
- 0
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Growth of bone marrow cells on porous ceramics in vitro. https://app.cochat.ai/papers/10.1002/jbm.820210106
- The paper
- Uchida, A., Nade, S., McCartney, E., & Ching, W. (1987). Growth of bone marrow cells on porous ceramics in vitro. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820210106
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.