Complement activation by hydroxyethylmethacrylate‐ethylmethacrylate copolymers
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Certain biomaterials, including nylon oxygenator and cellulosic dialysis membranes, are potent activators of human complement. In this study, the effect of polymers containing 2‐hydroxyethyl methacrylate (HEMA) on the human complement system was investigated. Copolymers of HEMA with ethylmethacrylate (EMA) varying from 100 to 40% HEMA in the monomer made by radiation initiation were used to coat glass discs. These were equilibrated with human plasma in vitro and the degree of complement activation was quantitated by C3a radio immunoassay. Significant activation was caused by copolymers made from monomers containing 60% or greater HEMA. A direct relationship between the amount of activation and the percentage of HEMA was found. The degree of activation by poly HEMA, when corrected for surface area, was quite similar to that observed for dialysis and oxygenator membranes. Similar observations were made when solid casts of crosslinked HEMA/N‐vinylpyrrolidone (NVP) copolymer gels were tested, but the magnitude of activation was much greater. The results are significant because complement activation may play an important role in the response to foreign surfaces, in both extravascular and intravascular settings. A new concept of molecular biocompatibility is proposed in which surfaces eliciting molecular transformations in any of the biological defense systems are deemed nonbiocompatible. By this criterion, the hydrogel poly‐HEMA, which has so frequently been thought of as biocompatible, is considered to be a molecularly nonbiocompatible material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chenoweth, D. E., Cooper, S. W., Hugli, T. E., Stewart, R. W., Blackstone, E. H., & Kirklin, J. W. (1981) · New England Journal of Medicine · doi:10.1056/nejm198102263040901 · Cited by 1,146
Interaction of high molecular weight kininogen, factor XII, and fibrinogen in plasma at interfaces
Vroman, L., Adams, A., Fischer, G., & Munoz, P. (1980) · Blood · doi:10.1182/blood.v55.1.156.156 · Cited by 781
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Cited by
Poly(ethylene glycol) in Drug Delivery: Pros and Cons as Well as Potential Alternatives
Knop, K., Hoogenboom, R., Fischer, D., & Schubert, U. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200902672 · Cited by 3,533
PEG — A versatile conjugating ligand for drugs and drug delivery systems
Kolate, A., Baradia, D., Patil, S., Vhora, I., Kore, G., & Misra, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.06.046 · Cited by 648
Modification of polysiloxane polymers for biomedical applications: a review
Abbasi, F., Mirzadeh, H., & Katbab, A. (2001) · Polymer International · doi:10.1002/pi.783 · Cited by 500
In vitro evaluation of the inflammatory potential of the silk fibroin
Santin, M., Motta, A., Freddi, G., & Cannas, M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990905)46:3<382::aid-jbm11>3.0.co;2-r · Cited by 444
Biocompatibility Testing of Branched and Linear Polyglycidol
Kainthan, R. K., Janzen, J., Levin, E., Devine, D. V., & Brooks, D. E. (2006) · Biomacromolecules · doi:10.1021/bm0504882 · Cited by 393
Metadata
- Authors
- Payne, M. S., & Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1987-07
- Volume
- 21
- Issue
- 7
- Pages
- 843-859
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2112524500
- Cited by
- 76
- References
- 3
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.