The DOI matches its Crossref record.
Heparin immobilization onto segmented polyurethaneurea surfaces—effect of hydrophilic spacers
Abstract
Heparin was immobilized onto segmented polyurethane‐urea surfaces (Biomer) using hydrophilic poly(ethylene oxide) spacers of different chain lengths. The use of the hydrophilic spacer, poly(ethylene oxide), reduces protein adsorption and subsequent platelet adhesion on the surface. In addition, the bioactivity of the immobilized heparin is enhanced by the incorporation of these spacers. Immobilized heparin bioactivity is shown to be a function of PEO spacer length. Use of hydrophilic PEO spacers demonstrates that immobilized heparin's bioactivity is consistently higher than that of the C 6 alkyl spacer, but heparin‐immobilized surfaces demonstrate no chain length effect on platelet adhesion, even though they show less platelet adhesion compared to Biomer controls. In the case of PEO‐grafted surfaces, platelet adhesion is decreased compared to Biomer controls, and C 6 alkyl spacer‐grafted surfaces, and exhibits a minimum at PEO 1000. In ex vivo A–A shunt experiments under low flow and low shear conditions, all heparinized surfaces exhibit significant prolongation of occlusion times compared to Biomer controls, indicating an ability of immobilized heparin to inhibit thrombosis in whole blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood compatibility of polyethylene oxide surfaces
LEE, J., LEE, H., & ANDRADE, J. (1995) · Progress in Polymer Science · doi:10.1016/0079-6700(95)00011-4 · Cited by 703
Phosphorylcholine-containing polymers for biomedical applications
Iwasaki, Y., & Ishihara, K. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2805-9 · Cited by 332
Remodeling of an acellular collagen graft into a physiologically responsive neovessel
Huynh, T., Abraham, G., Murray, J., Brockbank, K., Hagen, P.-O., & Sullivan, S. (1999) · Nature Biotechnology · doi:10.1038/15062 · Cited by 330
Surface modification using silanated poly(ethylene glycol)s
Jo, S., & Park, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00224-0 · Cited by 329
Self-citationImmobilization of heparin to EDC/NHS-crosslinked collagen. Characterization and in vitro evaluation
Wissink, M. J. B., Beernink, R., Pieper, J. S., Poot, A. A., Engbers, G. H. M., Beugeling, T., van Aken, W. G., & Feijen, J. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00164-2 · Cited by 311
Metadata
- Authors
- Park, K. D., Okano, T., Nojiri, C., & Kim, S. W.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1988-11
- Volume
- 22
- Issue
- 11
- Pages
- 977-992
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2087614924
- Cited by
- 227
- References
- 0
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heparin immobilization onto segmented polyurethaneurea surfaces—effect of hydrophilic spacers. https://app.cochat.ai/papers/10.1002/jbm.820221103
- The paper
- Park, K. D., Okano, T., Nojiri, C., & Kim, S. W. (1988). Heparin immobilization onto segmented polyurethaneurea surfaces—effect of hydrophilic spacers. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820221103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.