The DOI matches its Crossref record.
Ultra‐high‐strength absorbable self‐reinforced polyglycolide (SR‐PGA) composite rods for internal fixation of bone fractures: In vitro and in vivo study
Abstract
The ultra‐high‐strength, self‐reinforced (SR) absorbable polymeric composites, consisting of reinforcement elements, like fibers, and of matrix polymer which have the same chemical element composition as reinforcement, were defined. A method to manufacture self‐reinforced, absorbable polyglycolide (SR‐PGA) rods of polyglycolide sutures (Dexon) by sintering them partially together at elevated temperature and pressure was presented. The rods with nominal diameters of 1.5 mm, 2.0 mm, 3.2 mm, and 4.5 mm showed initial bending modulus and strength values of 8–15 GPa and 220–405 MPa, respectively. Their initial shear strengths were 165–255 MPa. The smallest rods (diam. 1.5 mm) lost their mechanical strength after implantation in the subcutis of rabbits in 4–5 weeks while the thickest rods retained their strength over 8 weeks. The ultra‐high‐strength SR‐PGA rods were concluded to be suitable for fixation of cancellous bone fractures, osteotomies, and epiphyseal plate fractures where the fixation is not exposed to excessive mechanical stresses and where the loads are predominantly of a shear nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
Mano, J. F., Sousa, R. A., Boesel, L. F., Neves, N. M., & Reis, R. L. (2004) · Composites Science and Technology · doi:10.1016/j.compscitech.2003.09.001 · Cited by 450
Biodegradable materials for bone defect repair
Wei, S., Ma, J.-X., Xu, L., Gu, X.-S., & Ma, X.-L. (2020) · Military Medical Research · doi:10.1186/s40779-020-00280-6 · Cited by 406
Metadata
- Authors
- Törmälä, P., Vasenius, J., Vainionpää, S., Laiho, J., Pohjonen, T., & Rokkanen, P.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 25
- Issue
- 1
- Pages
- 1-22
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2033299994
- Cited by
- 210
- References
- 0
- FWCI
- 11.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultra‐high‐strength absorbable self‐reinforced polyglycolide (SR‐PGA) composite rods for internal fixation of bone fractures: In vitro and in vivo study. https://app.cochat.ai/papers/10.1002/jbm.820250102
- The paper
- Törmälä, P., Vasenius, J., Vainionpää, S., Laiho, J., Pohjonen, T., & Rokkanen, P. (1991). Ultra‐high‐strength absorbable self‐reinforced polyglycolide (SR‐PGA) composite rods for internal fixation of bone fractures: In vitro and in vivo study. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820250102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.