CoChat

A light and electron microscopic study of the effects of surface topography on the behavior of cells attached to titanium‐coated percutaneous implants

Chehroudi, B., Gould, T. R. L., Brunette, D. M. · 1991 · Journal of Biomedical Materials Research
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Previous studies using light microscopy have demonstrated that micromachined grooved surfaces inhibit epithelial (E) downgrowth and affect cell orientation at the tissue/implant interface. This study investigates the ultrastructure of the epithelial and connective‐tissue attachment to titanium‐coated micromachined grooved, as well as smooth control, implant surfaces. V‐shaped grooves, 3, 10, or 22 μm deep, were produced in silicon wafers by micromachining, replicated in epoxy resin, and coated with 50‐nm titanium. These grooved, as well as smooth, titanium‐coated surfaces were implanted percutaneously in the parietal area of rats and after 7 days processed for electron microscopy. The tissue preparation technique used in this study enabled us to obtain ultrathin sections with few artifacts from the area of epithelial and connective‐tissue attachment. The histological observations demonstrated that E cells closely attached to, and interdigitated with, the 3‐μm and 10‐μm grooves. In contrast, E cells were not found inside the 22‐μm‐deep grooves and made contact only with the flat ridges between the grooves. As a general rule, fibroblasts (F) were oriented parallel to the long axis of the implants and produced a connective tissue capsule with 3‐μm and 10‐μm‐deep grooved surfaces as well as smooth surfaces. On the 22‐μm‐deep grooved surfaces, however, F inserted obliquely into the implant. The attachment of F to the titanium surface was mediated by two zones; a thin (≈︁20 nm), amorphous, electron dense zone immediately contacting the titanium surface, and a fine fibrillar zone extending from the amorphous zone to the cell membrane. As oblique orientation of F has been associated with the inhibition of epithelial downgrowth, micromachined grooved surfaces of appropriate dimensions have the potential to improve the performance of percutaneous devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820250310

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 107

Metadata

Authors
Chehroudi, B., Gould, T. R. L., & Brunette, D. M.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1991-03
Volume
25
Issue
3
Pages
387-405
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2064135579
Cited by
107
References
1
FWCI
7.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.