The DOI matches its Crossref record.
Glow discharge plasma deposition of tetraethylene glycol dimethyl ether for fouling‐resistant biomaterial surfaces
Abstract
The glow discharge plasma deposition (GDPD) of tetraethylene glycol dimethyl ether is introduced as a novel method for obtaining surfaces that are resistant to protein adsorption and cellular attachment. Analysis of films by x‐ray photoelectron spectroscopy and several biological assays indicate the formation of a foulingresistant, PEO‐like surface on several substrata (e.g., glass, polytetrafluoroethylene, polyethylene). Adsorption of 125 I‐radiolabelled proteins (fibrinogen, albumin and IgG) from buffer and plasma was very low (typically <20 ng/cm 2) when compared to the untreated substrata, which exhibited much higher levels of protein adsorption. Not all coated substrata adsorbed equal amounts of protein (e.g., coated glass samples typically adsorbed more protein than coated polyethylene or coated polytetrafluoroethylene samples), suggesting that the substratum used may affect the amount of protein adsorbed. Measurement of dynamic platelet adhesion, using epifluorescent video microscopy, and endothelial cell attachment further demonstrates the short‐term nonadhesiveness of these surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Self-citationSignificance of bacterial surface-active compounds in interaction of bacteria with interfaces
Neu, T. R. (1996) · Microbiological Reviews · doi:10.1128/mmbr.60.1.151-166.1996 · Cited by 667
Grafted poly(ethylene oxide) brushes as nonfouling surface coatings
Leckband, D., Sheth, S., & Halperin, A. (1999) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856299x00720 · Cited by 324
Shen, M., Martinson, L., Wagner, M. S., Castner, D. G., Ratner, B. D., & Horbett, T. A. (2002) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856202320253910 · Cited by 296
Self-citationReducing capsular thickness and enhancing angiogenesis around implant drug release systems
Ratner, B. D. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00502-8 · Cited by 271
Self-citation
Metadata
- Authors
- Löpez, G. P., Ratner, B. D., Tidwell, C. D., Haycox, C. L., Rapoza, R. J., & Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1992-04
- Volume
- 26
- Issue
- 4
- Pages
- 415-439
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2118734174
- Cited by
- 260
- References
- 0
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glow discharge plasma deposition of tetraethylene glycol dimethyl ether for fouling‐resistant biomaterial surfaces. https://app.cochat.ai/papers/10.1002/jbm.820260402
- The paper
- Löpez, G. P., Ratner, B. D., Tidwell, C. D., Haycox, C. L., Rapoza, R. J., & Horbett, T. A. (1992). Glow discharge plasma deposition of tetraethylene glycol dimethyl ether for fouling‐resistant biomaterial surfaces. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820260402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.