The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vitro and in vivo studies on bioabsorbable ultra‐high‐strength poly(L‐lactide) rods
Abstract
Ultra‐high‐strength poly(L‐lactide) (PLLA) rods were fabricated using a drawing technique. Rods with a diameter of 3.2 mm and a draw ratio of 2.5:1 showed initial bending strength and modulus values of 240 MPa and 13 GPa, respectively. The purpose of this study was to investigate the in vitro and in vivo degradation of PLLA rods with a draw ratio of 2.5:1. The greater the rod diameter, the longer the bending strength was maintained in phosphate buffered saline at 37°C. The bending strength retention of rods (diam. 3.2 mm) implanted in the subcutis of rabbits was almost equal to that of rods in the in vitro study, while those rods implanted in the medullary cavity of rabbit femora showed a slightly lower bending strength retention. Molecular weight was reduced to the greatest extent in the medullary cavity, followed by in the subcutis and in vitro. The weight of PLLA rods in the medullary cavity was reduced by 22% at 52 weeks and by 70% at 78 weeks after implantation. Histologically, no inflammatory or foreign body reaction was observed in the medullary cavity for 52 weeks. The drawn PLLA rods maintained a bending strength exceeding that of human cortical bone in the medullary canal for a period of 8 weeks, suggesting that the drawn PLLA rods may be useful in the repair of fractured human bones. © 1992 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Cited by
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Lu, H. H., El‐Amin, S. F., Scott, K. D., & Laurencin, C. T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10399 · Cited by 366
Safety assessment of polylactide (PLA) for use as a food-contact polymer
Conn, R. E., Kolstad, J. J., Borzelleca, J. F., Dixler, D. S., Filer, L. J., Ladu, B. N., & Pariza, M. W. (1995) · Food and Chemical Toxicology · doi:10.1016/0278-6915(94)00145-e · Cited by 344
Tsuji, H., & Ikada, Y. (2000) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(99)00111-1 · Cited by 329
Self-citation
Metadata
- Authors
- Matsusue, Y., Yamamuro, T., Oka, M., Shikinami, Y., Hyon, S., & Ikada, Y.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1992-12
- Volume
- 26
- Issue
- 12
- Pages
- 1553-1567
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1995395611
- Cited by
- 200
- References
- 1
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro and in vivo studies on bioabsorbable ultra‐high‐strength poly(L‐lactide) rods. https://app.cochat.ai/papers/10.1002/jbm.820261203
- The paper
- Matsusue, Y., Yamamuro, T., Oka, M., Shikinami, Y., Hyon, S., & Ikada, Y. (1992). In vitro and in vivo studies on bioabsorbable ultra‐high‐strength poly(L‐lactide) rods. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820261203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.