CoChat

Complement activation on solid surfaces as determined by C3 deposition and hemolytic consumption

Liu, Li, Elwing, Hans · 1994 · Journal of Biomedical Materials Research
Cited by 38

The DOI matches its Crossref record.

Abstract

Complement activation was investigated on hydrophilic and hydrophobic glass beads incubated in serum. Very little complement activation was detected with these surfaces, as indicated by a hemolytic assay and by measurement of the amount of iC3b appearing in the solution. However, preadsorption with IgG at the hydrophobic and hydrophilic beads resulted in complement activation on both surfaces. We also investigated dependent deposition of C3 at hydrophobic and hydrophilic silicon surfaces when the complement was activated. The chemistry of those surfaces is similar to the hydrophobic and hydrophilic beads. Ellipsometry, an optical method, was used for determination of the amounts of oraganic material deposited at the surface. C3 deposition was observed at the IgG precoated hydrophobic surface but not at the IgG‐coated hydrophilic surface. The absence of C3 deposition at the hydrophilic surface was probably due to reversible binding of IgG. However, precoating of the hydrophilic surface with a double layer of IgG and anti‐IgG resulted in C3 deposition also at the hydrophilic surface. The results illustrate that methods based on measuring deposition of C3 at surfaces, such as immunofluorescence or ellipsometry, cannot exclude surface‐associated complement activation that is probably due to reversible binding of the complement components of the activated molecule. On the other hand, it has previously been shown that determination of complement activation in solution with the use of a C3a assay cannot exclude surface‐associated activation due to immobilization of C3a at the surface.1 This methodologic question is an important issue because factors such as C3a and C5a act as soluble anaphylatoxins, whereas deposited factors such as C3 act as cellular receptors. © 1994 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820280703

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 38

Metadata

Authors
Liu, L., & Elwing, H.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1994-07
Volume
28
Issue
7
Pages
767-773
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2014136039
Cited by
38
References
0
FWCI
1.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complement activation on solid surfaces as determined by C3 deposition and hemolytic consumption. https://app.cochat.ai/papers/10.1002/jbm.820280703
The paper
Liu, L., & Elwing, H. (1994). Complement activation on solid surfaces as determined by C3 deposition and hemolytic consumption. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820280703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.