Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effect of parallel surface microgrooves and surface energy on cell growth

Open access
Den Braber, E. T., de Ruijter, J. E., Smits, H. T. J., Ginsel, L. A., von Recum, A. F., Jansen, J. A.·1995·Journal of Biomedical Materials Research

Abstract

To evaluate the effect of surface treatment and surface microtexture on cellular behavior, smooth and microtextured silicone substrata were produced. The microtextured substrata possessed parallel surface grooves with a width and spacing of 2.0 (SilD02), 5.0 (SilD05), and 10 μm (SilD10). The groove depth was approximately 0.5 μm. Subsequently, these substrata were either left untreated (NT) or treated by ultraviolet irradiation (UV), radiofrequency glow discharge treatment (RFGD), or both (UVRFGD). After characterization of the substrata, rat dermal fibroblasts (RDF) were cultured on the UV, RFGD, and UVRFGD treated surfaces for 1, 3, 5, and 7 days. Comparison between the NT and UV substrata revealed that UV treatment did not influence the contact angles and surface energies of surfaces with a similar surface topography. However, the contact angles of the RFGD and UVRFGD substrata were significantly smaller than those of the UV and NT substrata. The dimension of the surface microevents did not influence the wettability characteristics. Cell culture experiments revealed that RDF cell growth on UV‐treated surfaces was lower than on the RFGD and UVRFGD substrata. SEM examination demonstrated that the parallel surface grooves on the SilD02 and SilD05 substrata were able to induce stronger cell orientation and alignment than the events on SilD10 surfaces. By combining all of our findings, the most important conclusion was that physicochemical parameters such as wettability and surface free energy influence cell growth but play no measurable role in the shape and orientation of cells on microtextured surfaces. © 1995 John Wiley & Sons, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820290411

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 221

Metadata

Authors
Den Braber, E. T., de Ruijter, J. E., Smits, H. T. J., Ginsel, L. A., von Recum, A. F., & Jansen, J. A.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1995-04
Volume
29
Issue
4
Pages
511-518
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2133272529
Cited by
221
References
1
FWCI
2.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of parallel surface microgrooves and surface energy on cell growth. https://app.cochat.ai/papers/10.1002/jbm.820290411
The paper
Den Braber, E. T., de Ruijter, J. E., Smits, H. T. J., Ginsel, L. A., von Recum, A. F., & Jansen, J. A. (1995). Effect of parallel surface microgrooves and surface energy on cell growth. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820290411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.