The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Protein‐rejecting ability of surface‐bound dextran in end‐on and side‐on configurations: Comparison to PEG
Abstract
There is much interest in attaching polyethylene glycol (PEG) and other hydrophilic, neutral polymers to surfaces to reduce the extent of protein and cell adsorption. Interestingly, these same surface‐bound polymers are effective in masking surface charge and reducing electrokinetic effects such as particle electrophoretic mobility, streaming potential, and electroosmosis. It is apparent that similar molecular properties are responsible for both protein and cell rejection and reduction of electrokinetic effects. In this work we compared the fibrinogen‐rejecting ability and the effect on electrophoretic mobility of three polymer coatings bound to polystyrene. The three polymers were side‐bound dextran, end‐bound dextran, and end‐bound PEG. The results of these measurements were used to elucidate the importance of polymer packing density and polymer layer thickness on protein adsorption and reduction of electrokinetic effects. Protein adsorption appears not to be sensitive to polymer layer thickness or the presence of dilute polymer tails in a surface coating, while electrokinetic effects are. Protein adsorption is, however, very sensitive to the availability of exposed surface. Finally, the unique effectiveness of PEG is apparent in this research as in previous studies. © 1995 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, Z., Malik, A., & Lee, M. L. (1993) · Analytical Chemistry · doi:10.1021/ac00068a008 · Cited by 102
Cited by
Parameters influencing the stealthiness of colloidal drug delivery systems
Vonarbourg, A., Passirani, C., Saulnier, P., & Benoit, J.-P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.039 · Cited by 740
Block copolymer micelles for delivery of gene and related compounds
Kakizawa, Y., & Kataoka, K. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00017-0 · Cited by 738
Kingshott, P., Thissen, H., & Griesser, H. J. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00334-9 · Cited by 537
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Stealth Coating of Nanoparticles in Drug-Delivery Systems
Fam, S. Y., Chee, C. F., Yong, C. Y., Ho, K. L., Mariatulqabtiah, A. R., & Tan, W. S. (2020) · Nanomaterials · doi:10.3390/nano10040787 · Cited by 422
Metadata
- Authors
- Österberg, E., Bergström, K., Holmberg, K., Schuman, T. P., Riggs, J. A., Burns, N. L., Van Alstine, J. M., & Harris, J. M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1995-06
- Volume
- 29
- Issue
- 6
- Pages
- 741-747
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2023619846
- Cited by
- 247
- References
- 1
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.