The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tissue engineered bone: Measurement of nutrient transport in three‐dimensional matrices
Abstract
The classic paradigm for in vitro tissue engineering of bone involves the isolation and culture of donor osteoblasts or osteoprogenitor cells within three‐dimensional (3D) scaffold biomaterials under conditions that support tissue growth and mineralized osteoid formation. Our studies focus on the development and utilization of new dynamic culture technologies to provide adequate nutrient flux within 3D scaffolds to support ongoing tissue formation. In this study, we have developed a basic one‐dimensional (1D) model to characterize the efficiency of passive nutrient diffusion and transport flux to bone cells within 3D scaffolds under static and dynamic culture conditions. Internal fluid perfusion within modeled scaffolds increased rapidly with increasing pore volume and pore diameter to a maximum of approximately 1% of external fluid flow. In contrast, internal perfusion decreased significantly with increasing pore channel tortuosity. Calculations of associated nutrient flux indicate that static 3D culture and some inappropriately designed dynamic culture environments lead to regions of insufficient nutrient concentration to maintain cell viability, and can result in steep nutrient concentration gradients within the modeled constructs. These quantitative studies provide a basis for development of new dynamic culture methodologies to overcome the limitations of passive nutrient diffusion in 3D cell‐scaffold composite systems proposed for in vitro tissue engineering of bone. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 357–367, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Cited by
Karande, T. S., Ong, J. L., & Agrawal, C. M. (2004) · Annals of Biomedical Engineering · doi:10.1007/s10439-004-7825-2 · Cited by 457
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Cell Responses to Surface and Architecture of Tissue Engineering Scaffolds
Chang, H.-I., & Wang, Y. (2011) · Regenerative Medicine and Tissue Engineering - Cells and Biomaterials · doi:10.5772/21983 · Cited by 393
Cheng, C. W., Solorio, L. D., & Alsberg, E. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.12.012 · Cited by 358
Chitosan scaffolds: Interconnective pore size and cartilage engineering
GRIFFON, D., SEDIGHI, M., SCHAEFFER, D., EURELL, J., & JOHNSON, A. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.12.007 · Cited by 351
Metadata
- Authors
- Botchwey, E. A., Dupree, M. A., Pollack, S. R., Levine, E. M., & Laurencin, C. T.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-09-12
- Volume
- 67A
- Issue
- 1
- Pages
- 357-367
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2072652998
- Cited by
- 207
- References
- 1
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue engineered bone: Measurement of nutrient transport in three‐dimensional matrices. https://app.cochat.ai/papers/10.1002/jbm.a.10111
- The paper
- Botchwey, E. A., Dupree, M. A., Pollack, S. R., Levine, E. M., & Laurencin, C. T. (2003). Tissue engineered bone: Measurement of nutrient transport in three‐dimensional matrices. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.