The DOI matches its Crossref record.
Osteogenecity of octacalcium phosphate coatings applied on porous metal implants
Open accessAbstract
The biomimetic route allows the homogeneous deposition of calcium phosphate (Ca‐P) coatings on porous implants by immersion in simulated physiologic solution. In addition, various Ca‐P phases, such as octacalcium phosphate (OCP) or bone‐like carbonated apatite (BCA), which are stable only at low temperatures, can be deposited. In this pilot study, experiments were designed with a twofold‐purpose: (1) to investigate the osteoinduction of OCP‐coated and noncoated porous tantalum cylinders and of dense titanium alloy cylinders (5 mm in diameter and 10 mm in length) in the back muscle of goats at 12 and 24 weeks (n = 4); and (2) to compare the osteogenic potentials of BCA‐coated, OCP‐coated, and bare porous tantalum cylinders in a gap of 1 mm created in the femoral condyle of a goat at 12 weeks (n = 2). In the goat muscle, after 12 weeks the OCP‐coated porous cylinder had induced ectopic bone as well as bone within the cavity of the OCP‐coated dense titanium cylinder. In the femoral condyle, bone did not fill the gap in any of the porous implants. In contrast with the two other groups, OCP‐coated porous cylinders exhibited bone formation in the center of the implant. The nature of the Ca‐P coating, via its microstructure, its dissolution rate, and its specific interactions with body fluids, may influence the osteogenecity of the Ca‐P biomaterial. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 779–788, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Bioceramics of calcium orthophosphates
Dorozhkin, S. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.050 · Cited by 1,338
Calcium phosphates in biomedical applications: materials for the future?
Habraken, W., Habibovic, P., Epple, M., & Bohner, M. (2016) · Materials Today · doi:10.1016/j.mattod.2015.10.008 · Cited by 857
Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
Metadata
- Authors
- Barrère, F., van der Valk, C. M., Dalmeijer, R. A. J., Meijer, G., van Blitterswijk, C. A., de Groot, K., & Layrolle, P.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-08-07
- Volume
- 66A
- Issue
- 4
- Pages
- 779-788
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2106121106
- Cited by
- 248
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Osteogenecity of octacalcium phosphate coatings applied on porous metal implants. https://app.cochat.ai/papers/10.1002/jbm.a.10454
- The paper
- Barrère, F., van der Valk, C. M., Dalmeijer, R. A. J., Meijer, G., van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2003). Osteogenecity of octacalcium phosphate coatings applied on porous metal implants. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.