CoChat

Human serum opsonization of orthopedic biomaterial particles: Protein‐binding and monocyte/macrophage activation in vitro

Sun, Doo‐Hoon, Trindade, Michael C. D., Nakashima, Yasuharu, Maloney, William J., Goodman, Stuart B., Schurman, David J., Smith, R. Lane · 2003 · Journal of Biomedical Materials Research Part A
Cited by 55

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Wear particles generated after total joint arthroplasty activate monocyte/macrophages and incite formation of a granulomatous periprosthetic tissue associated with bone loss and implant loosening. This study tested the hypothesis that selective opsonization of orthopedic implant biomaterial wear particles by human serum proteins influences monocyte/macrophage activation. Serum protein binding to metallic, polymeric, and ceramic particles was determined by one‐dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS‐PAGE). Individual proteins bound to particles were subsequently identified using two‐dimensional SDS‐PAGE, microsequencing techniques, and SWISS‐PROT analysis. Effects of selective protein opsonization on particle‐induced monocyte/macrophage activation were assessed by quantification of interleukin‐1beta, interleukin‐6, and tumor necrosis factor‐alpha release. Results from one‐dimensional gel analyses revealed distinct serum protein‐binding patterns specific for each material tested. Two‐dimensional gel analysis together with amino acid sequencing of the prominent protein species confirmed the presence of albumin and alpha‐1‐antitrypsin bound to all particles tested. In contrast to the metallic particles, apolipoprotein was a major species associated with polymeric particles. Opsonization of PMMA particles with purified preparations of each of the identified proteins showed that albumin significantly enhanced particle‐induced monocyte/macrophage activation. These data confirm orthopedic biomaterial specific binding of human serum proteins and demonstrate that albumin exacerbates particle‐induced monocyte/macrophage activation. Alterations in the chemical and surface properties of orthopedic biomaterials to modulate protein interactions may improve implant longevity. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 290–298, 2003

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.10477

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sun, D., Trindade, M. C. D., Nakashima, Y., Maloney, W. J., Goodman, S. B., Schurman, D. J., & Smith, R. L.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-03-25
Volume
65A
Issue
2
Pages
290-298
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1978363136
Cited by
55
References
1
FWCI
4.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.