The DOI matches its Crossref record.
A fibrin‐based arterial media equivalent
Abstract
We report here, with respect to collagen production and the mechanical properties of a fibrin‐based media equivalent (ME), on our efforts to optimize the culture conditions of neonatal SMCs entrapped in tubular fibrin gels. We examined several factors, including the concentration of fibrinolysis inhibitor, the cell source and initial number, the addition of TGF‐β and insulin to the culture medium, and the time in culture. We found that varying the concentration of ϵ‐aminocaproic acid (ACA), an inhibitor of fibrinolysis, did not affect the collagen production, but that lower concentrations resulted in a compromised physical integrity of the ME. While use of neonatal SMCs yielded superior results over adult SMCs, a higher initial cell number did not improve results. The addition of 1 ng/mL of TGF‐β to the medium increased the collagen content fourfold and the ultimate tensile strength (UTS) and modulus approximately tenfold after 3 weeks, while the addition of both TGF‐β and insulin improved collagen content sixfold and UTS and modulus almost 20‐fold. Additional TGF‐β (5 ng/mL) did not improve any of the properties measured, but additional time in culture did. Samples incubated for 6 weeks with TGF‐β and insulin contained about seven times the amount of collagen and had a three‐times higher UTS and modulus than did samples incubated for only 3 weeks. When compared to collagen MEs, the fibrin MEs compacted to a greater extent and were both stronger and stiffer when cultured under the same conditions, having after 6 weeks a tensile modulus and ultimate tensile strength similar to those of rat abdominal aorta. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 550–561, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Self-citationCell encapsulation using biopolymer gels for regenerative medicine
Hunt, N. C., & Grover, L. M. (2010) · Biotechnology Letters · doi:10.1007/s10529-010-0221-0 · Cited by 434
Biomaterials for Vascular Tissue Engineering
Ravi, S., & Chaikof, E. L. (2010) · Regenerative Medicine · doi:10.2217/rme.09.77 · Cited by 387
Beamish, J. A., He, P., Kottke-Marchant, K., & Marchant, R. E. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0630 · Cited by 383
Metadata
- Authors
- Grassl, E. D., Oegema, T. R., & Tranquillo, R. T.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-07-29
- Volume
- 66A
- Issue
- 3
- Pages
- 550-561
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2079369870
- Cited by
- 196
- References
- 0
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fibrin‐based arterial media equivalent. https://app.cochat.ai/papers/10.1002/jbm.a.10589
- The paper
- Grassl, E. D., Oegema, T. R., & Tranquillo, R. T. (2003). A fibrin‐based arterial media equivalent. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10589
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.