Physical characterization of controlled release of paclitaxel from the TAXUS™ Express2™ drug‐eluting stent
Abstract
The polymer carrier technology in the TAXUS™ drug‐eluting stent consists of a thermoplastic elastomer poly(styrene‐b‐isobutylene‐b‐styrene) (SIBS) with microphase‐separated morphology resulting in optimal properties for a drug‐delivery stent coating. Comprehensive physical characterization of the stent coatings and cast film formulations showed that paclitaxel (PTx) exists primarily as discrete nanoparticles embedded in the SIBS matrix. Thermal and chemical analysis did not show any evidence of solubility of PTx in SIBS or of any molecular miscibility between PTx and SIBS. Atomic force microscope data images revealed for the first time three‐dimensional stent coating surfaces at high spatial resolutions in air and in situ under phosphate‐buffered saline as drug was released. PTx release involves the initial dissolution of drug particles from the PTx/SIBS coating surface. Morphological examination of the stent coatings in vitro supported an early burst release in most formulations because of surface PTx followed by a sustained slower release of PTx from the bulk coating. The in vitro PTx release kinetics were dependent on the formulation and correlated to the drug‐to‐polymer ratio. Atomic force microscopy analysis confirmed this correlation and further supported the concept of a matrix‐based drug‐release coating. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 71A: 625–634, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
50th Anniversary Perspective: Block Polymers—Pure Potential
Bates, C. M., & Bates, F. S. (2017) · Macromolecules · doi:10.1021/acs.macromol.6b02355 · Cited by 788
Jagur‐Grodzinski, J. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.729 · Cited by 394
Metadata
- Authors
- Ranade, S. V., Miller, K. M., Richard, R. E., Chan, A. K., Allen, M. J., & Helmus, M. N.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2004-10-27
- Volume
- 71A
- Issue
- 4
- Pages
- 625-634
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1983608660
- Cited by
- 185
- References
- 0
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical characterization of controlled release of paclitaxel from the TAXUS™ Express2™ drug‐eluting stent. https://app.cochat.ai/papers/10.1002/jbm.a.30188
- The paper
- Ranade, S. V., Miller, K. M., Richard, R. E., Chan, A. K., Allen, M. J., & Helmus, M. N. (2004). Physical characterization of controlled release of paclitaxel from the TAXUS™ Express2™ drug‐eluting stent. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.