Nanoindentation of injection molded PLA and self‐reinforced composite PLA after in vitro conditioning for three months
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Poly(lactic acid) (PLA) is used for medical devices such as sutures or orthopedic screws. A standard way to determine the loss of mechanical properties of a degradable polymer would be to soak the polymer in phosphate buffered saline (PBS) and test the desired property as a function of immersion time. This method is not sensitive enough to discern changes in mechanical properties through the cross‐section of the polymer and neglects the degradation that is occurring at the molecular level. This article presents results of a nanoindentation study carried out with PLA. The modulus and hardness of PLA is characterized as a function of processing method, immersion time in PBS, and location of the indent. Measuring local properties with the nanoindenter allowed detection of differences in material properties as a function of all three of these variables. The mechanical properties on the edge were lower than the interior of the sample after in vitro degradation, and changes were seen earlier for nanoindentation than for traditional flexural or tensile tests. The nanoindenter is a valuable tool for quantifying changes in material properties and may have applicability for accelerated tests to screen biomaterials. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Cited by
Fluorescent PLLA-nanodiamond composites for bone tissue engineering
Zhang, Q., Mochalin, V. N., Neitzel, I., Knoke, I. Y., Han, J., Klug, C. A., Zhou, J. G., Lelkes, P. I., & Gogotsi, Y. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.090 · Cited by 399
“23 GPa) [29].”
Effect of thermo-mechanical cycles on the physico-chemical properties of poly(lactic acid)
Pillin, I., Montrelay, N., Bourmaud, A., & Grohens, Y. (2008) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2007.12.005 · Cited by 289
Development of self-reinforced polymer composites
Gao, C., Yu, L., Liu, H., & Chen, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.09.005 · Cited by 226
Thomas, V., Jose, M. V., Chowdhury, S., Sullivan, J. F., Dean, D. R., & Vohra, Y. K. (2006) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856206778366022 · Cited by 208
Bio-resorbable polymer stents: a review of material progress and prospects
McMahon, S., Bertollo, N., Cearbhaill, E. D. O., Salber, J., Pierucci, L., Duffy, P., Dürig, T., Bi, V., & Wang, W. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.05.002 · Cited by 194
Metadata
- Authors
- Wright‐Charlesworth, D. D., Miller, D. M., Miskioglu, I., & King, J. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-07-12
- Volume
- 74A
- Issue
- 3
- Pages
- 388-396
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2065862444
- Cited by
- 65
- References
- 1
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoindentation of injection molded PLA and self‐reinforced composite PLA after in vitro conditioning for three months. https://app.cochat.ai/papers/10.1002/jbm.a.30353
- The paper
- Wright‐Charlesworth, D. D., Miller, D. M., Miskioglu, I., & King, J. A. (2005). Nanoindentation of injection molded PLA and self‐reinforced composite PLA after in vitro conditioning for three months. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.