The DOI matches its Crossref record.
Topographic guidance of endothelial cells on silicone surfaces with micro‐ to nanogrooves: Orientation of actin filaments and focal adhesions
Abstract
To mimic the uniformly elongated endothelium in natural linear vessels, bovine aortic endothelial cells (BAECs) are cultured on micro‐ to nanogrooved, model poly(dimethylsiloxane) (PDMS) substrates preadsorbed with about 300 ng/cm 2 of fibronectin. BAEC alignment, elongation, and projected area were investigated for channel depths of 200 nm, 500 nm, 1 μm, and 5 μm, as well as smooth surfaces. Except for the 5 μm case, the ridge and channel widths were held nearly constant about 3.5 μm. With increasing channel depth, the percentage of aligned BAECs increased by factors of 2, 2, 1.8, and 1.7 for 1, 4, 24, and 48 h. Maximum alignment, about 90%, was observed for 1 μm deep channels at 1 h. The alignment of BAECs on grooved PDMS was maintained at least until cells reached near confluence. F‐actin and vinculin at focal adhesions also aligned with channel direction. Analysis of confocal microscopy images showed that focal adhesions localized at corners and along the sidewalls of 1‐μm deep channels. In contrast, focal adhesions could not form on the bottom of the 5‐μm deep channels. Cell proliferation was similar on grooved and smooth substrates. In summary, PDMS substrates engraved with micro‐ and nanochannels provide a powerful method for investigating the interplay between topography and cell/cytoskeletal alignment. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engineering Substrate Topography at the Micro‐ and Nanoscale to Control Cell Function
Bettinger, C. J., Langer, R., & Borenstein, J. T. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805179 · Cited by 1,258
Electrospinning polyaniline-contained gelatin nanofibers for tissue engineering applications
Li, M., Guo, Y., Wei, Y., MacDiarmid, A. G., & Lelkes, P. I. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.037 · Cited by 856
Self-citationPhysical influences of the extracellular environment on cell migration
Charras, G., & Sahai, E. (2014) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3897 · Cited by 702
Engineering microscale topographies to control the cell–substrate interface
Nikkhah, M., Edalat, F., Manoucheri, S., & Khademhosseini, A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.03.079 · Cited by 640
Biopolymer-based functional composites for medical applications
Park, S.-B., Lih, E., Park, K.-S., Joung, Y. K., & Han, D. K. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.12.003 · Cited by 429
Metadata
- Authors
- Uttayarat, P., Toworfe, G. K., Dietrich, F., Lelkes, P. I., & Composto, R. J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-08-18
- Volume
- 75A
- Issue
- 3
- Pages
- 668-680
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2081656933
- Cited by
- 207
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Topographic guidance of endothelial cells on silicone surfaces with micro‐ to nanogrooves: Orientation of actin filaments and focal adhesions. https://app.cochat.ai/papers/10.1002/jbm.a.30478
- The paper
- Uttayarat, P., Toworfe, G. K., Dietrich, F., Lelkes, P. I., & Composto, R. J. (2005). Topographic guidance of endothelial cells on silicone surfaces with micro‐ to nanogrooves: Orientation of actin filaments and focal adhesions. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30478
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.