The influence of functional groups of self‐assembled monolayers on fibrous capsule formation and cell recruitment
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The contribution of the surface chemistry of an implant to the thickness of the fibrous capsule formed after implantation was herein investigated. For that, self‐assembled monolayers (SAMs) of alkanethiols on gold with different terminal functional groups (COOH, OH, and CH 3) were used. These surfaces were implanted in subcutaneous air pouches of BALB/c mice and the ensuing fibrous capsules were evaluated and compared with the initial inflammatory response caused by the implant. The thickness of the fibrous capsules that are under organization around the implant was measured 1 week after implantation by histology. Inflammatory exudates were collected from the air pouches 24 h after the implantation of SAMs and were analyzed by flow cytometry. A significant increase in the thickness of fibrous capsules was seen around implanted CH 3‐terminated SAMs, and also in gold surfaces, in comparison with the air pouch wall of sham‐operated mice and of COOH‐ and OH‐covered SAMs. The CH 3‐coated implants also recruited higher numbers of inflammatory cells; this enhancement involved a significant number of Mac‐1+ cells. Our data indicate that implant surfaces coated with CH 3 induce thick fibrous capsules and this may be the result of the stronger inflammatory effect of CH 3 in comparison with COOH or OH chemical groups. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Cited by
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Biomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
“However, negatively charged carboxylated surfaces smooth inflammatory reactions [186,190,196] and trigger alterations in the migratory behavior and function of circulating macrophages, thus abrogating macrophage-mediated inflammatory activity and promoting regulatory T cell phenotypes [189].”
BackgroundThe pathology of the foreign body reaction against biomaterials
Klopfleisch, R., & Jung, F. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35958 · Cited by 524
Cell/Material Interfaces: Influence of Surface Chemistry and Surface Topography on Cell Adhesion
Anselme, K., Ploux, L., & Ponche, A. (2010) · Journal of Adhesion Science and Technology · doi:10.1163/016942409x12598231568186 · Cited by 291
Macrophage and dendritic cell phenotypic diversity in the context of biomaterials
Kou, P. M., & Babensee, J. E. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32971 · Cited by 190
Metadata
- Authors
- Barbosa, J. N., Madureira, P., Barbosa, M. A., & Águas, A. P.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-12-05
- Volume
- 76A
- Issue
- 4
- Pages
- 737-743
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2004874831
- Cited by
- 81
- References
- 2
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.