The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Poly‐L‐lactic acid/hydroxyapatite hybrid membrane for bone tissue regeneration
Abstract
Poly‐L‐lactic acid (PLLA)/hydroxyapatite (HA) hybrid membranes were fabricated via electrospinning of the PLLA/HA dispersion for use in bone tissue regeneration. The structural properties and morphologies of PLLA and PLLA/HA hybrid membrane were investigated by measuring the Brunauer‐Emmett‐Teller specific surface area, observations of SEM, and TEM. The dispersion and integrating of HA nanoparticles in the hybrid membrane were studied by energy dispersion X‐ray analysis and FTIR. The mechanical properties of PLLA/HA membrane were also measured by tensile tests. For exploring biological behaviors of the hybrid membrane, in vitro degradation tests were carried out. The osteoblast cell (MG‐63) was cultured in PLLA/HA hybrid membrane extract containing medium; the cell adhesion and growth capability were investigated by SEM observation and MTT assay. HA nanoparticles were not only dispersed in the PLLA but also reacted with the functional group of PLLA, resulting in strong surface bonding and high tensile strength of hybrid membrane. The cell adhesion and growth on the PLLA/HA hybrid membrane were far better than those on the pure PLLA membrane, which proves that the PLLA/HA hybrid membrane can be one of the promising biomaterials for bone tissue regeneration. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischer, E. W., Sterzel, H. J., & Wegner, G. (1973) · Kolloid-Zeitschrift und Zeitschrift für Polymere · doi:10.1007/bf01498927 · Cited by 1,704
Cited by
Electrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Use of electrospinning technique for biomedical applications
Agarwal, S., Wendorff, J. H., & Greiner, A. (2008) · Polymer · doi:10.1016/j.polymer.2008.09.014 · Cited by 1,822
Zhang, Y., Venugopal, J. R., El-Turki, A., Ramakrishna, S., Su, B., & Lim, C. T. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.038 · Cited by 702
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
Electrospun nanostructured scaffolds for bone tissue engineering
Prabhakaran, M. P., Venugopal, J., & Ramakrishna, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.007 · Cited by 430
Metadata
- Authors
- Sui, G., Yang, X., Mei, F., Hu, X., Chen, G., Deng, X., & Ryu, S.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-02-12
- Volume
- 82A
- Issue
- 2
- Pages
- 445-454
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2013799620
- Cited by
- 215
- References
- 1
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly‐L‐lactic acid/hydroxyapatite hybrid membrane for bone tissue regeneration. https://app.cochat.ai/papers/10.1002/jbm.a.31166
- The paper
- Sui, G., Yang, X., Mei, F., Hu, X., Chen, G., Deng, X., & Ryu, S. (2007). Poly‐L‐lactic acid/hydroxyapatite hybrid membrane for bone tissue regeneration. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31166
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.