Fabrication and characterization of novel nano‐ and micro‐HA/PCL composite scaffolds using a modified rapid prototyping process
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Novel three‐dimensional scaffolds consisting of nano‐ and microsized hydroxyapatite (HA)/poly(ϵ‐caprolactone) (PCL) composite were fabricated using a modified rapid‐prototyping (RP) technique for bone tissue engineering applications. The size of the nano‐HA ranged from 20 to 90 nm, whereas that of the micro‐HA ranged from 20 to 80 μm. The scaffold macropores were well interconnected, with a porosity of 72–73% and a pore size of 500 μm. The compressive modulus of the nano‐HA/PCL and micro‐HA/PCL scaffolds was 3.187 ± 0.06 and 1.345 ± 0.05 MPa, respectively. The higher modulus of the nano‐HA/PCL composite (n‐HPC) was to be likely caused by a dispersion strengthening effect. The attachment and proliferation of MG‐63 cells on n‐HPC were better than that on the micro‐HA/PCL composite (m‐HPC) scaffold. The n‐HPC was more hydrophilic than the m‐HPC because of the greater surface area of HA exposed to the scaffold surface. This may give rise to better cell attachment and proliferation. Bioactive n‐HA/PCL composite scaffold prepared using a modified RP technique has a potential application in bone tissue engineering. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Bone tissue engineering: A review in bone biomimetics and drug delivery strategies
Porter, J. R., Ruckh, T. T., & Popat, K. C. (2009) · Biotechnology Progress · doi:10.1002/btpr.246 · Cited by 809
Scaffolding Strategies for Tissue Engineering and Regenerative Medicine Applications
Pina, S., Ribeiro, V. P., Marques, C. F., Maia, F. R., Silva, T. H., Reis, R. L., & Oliveira, J. M. (2019) · Materials · doi:10.3390/ma12111824 · Cited by 493
Composites by rapid prototyping technology
Kumar, S., & Kruth, J.-P. (2010) · Materials & Design · doi:10.1016/j.matdes.2009.07.045 · Cited by 463
Nano-Hydroxyapatite Composite Biomaterials for Bone Tissue Engineering—A Review
Venkatesan, J., & Kim, S.-K. (2014) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2014.1893 · Cited by 348
Self-citation
Metadata
- Authors
- Heo, S., Kim, S., Wei, J., Hyun, Y., Yun, H., Kim, D., Shin, J. W., & Shin, J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2008-04-22
- Volume
- 89A
- Issue
- 1
- Pages
- 108-116
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2052801240
- Cited by
- 131
- References
- 1
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.