Cell response of anodized nanotubes on titanium and titanium alloys
Abstract
Titanium and titanium alloy implants that have been demonstrated to be more biocompatible than other metallic implant materials, such as Co–Cr alloys and stainless steels, must also be accepted by bone cells, bonding with and growing on them to prevent loosening. Highly ordered nanoporous arrays of titanium dioxide that form on titanium surface by anodic oxidation are receiving increasing research interest due to their effectiveness in promoting osseointegration. The response of bone cells to implant materials depends on the topography, physicochemistry, mechanics, and electronics of the implant surface and this influences cell behavior, such as adhesion, proliferation, shape, migration, survival, and differentiation; for example the existing anions on the surface of a titanium implant make it negative and this affects the interaction with negative fibronectin (FN). Although optimal nanosize of reproducible titania nanotubes has not been reported due to different protocols used in studies, cell response was more sensitive to titania nanotubes with nanometer diameter and interspace. By annealing, amorphous TiO 2 nanotubes change to a crystalline form and become more hydrophilic, resulting in an encouraging effect on cell behavior. The crystalline size and thickness of the bone‐like apatite that forms on the titania nanotubes after implantation are also affected by the diameter and shape. This review describes how changes in nanotube morphologies, such as the tube diameter, the thickness of the nanotube layer, and the crystalline structure, influence the response of cells. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 2726–2739, 2013.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Significance of synthetic nanostructures in dictating cellular response
Yim, E. K. F., & Leong, K. W. (2005) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2004.11.008 · Cited by 281
Cited by
Bone regeneration performance of surface-treated porous titanium
Amin Yavari, S., van der Stok, J., Chai, Y. C., Wauthle, R., Tahmasebi Birgani, Z., Habibovic, P., Mulier, M., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.054 · Cited by 297
Visible-Light Active Titanium Dioxide Nanomaterials with Bactericidal Properties
Liao, C., Li, Y., & Tjong, S. C. (2020) · Nanomaterials · doi:10.3390/nano10010124 · Cited by 263
Metadata
- Authors
- Minagar, S., Wang, J., Berndt, C. C., Ivanova, E. P., & Wen, C.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2013-07-30
- Volume
- 101A
- Issue
- 9
- Pages
- 2726-2739
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2142298268
- Cited by
- 194
- References
- 1
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cell response of anodized nanotubes on titanium and titanium alloys. https://app.cochat.ai/papers/10.1002/jbm.a.34575
- The paper
- Minagar, S., Wang, J., Berndt, C. C., Ivanova, E. P., & Wen, C. (2013). Cell response of anodized nanotubes on titanium and titanium alloys. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.34575
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.