Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 96 of the 96 references it cites were found in a registry or an index.

An overview of recent advances in designing orthopedic and craniofacial implants

Open access
Mantripragada, Venkata P., Lecka‐Czernik, Beata, Ebraheim, Nabil A., Jayasuriya, Ambalangodage C.·2013·Journal of Biomedical Materials Research Part A

Abstract

Great deal of research is still going on in the field of orthopedic and craniofacial implant development to resolve various issues being faced by the industry today. Despite several disadvantages of the metallic implants, they continue to be used, primarily because of their superior mechanical properties. In order to minimize the harmful effects of the metallic implants and its by‐products, several modifications are being made to these materials, for instance nickel‐free stainless steel, cobalt‐chromium and titanium alloys are being introduced to eliminate the toxic effects of nickel being released from the alloys, introduce metallic implants with lower modulus, reduce the cost of these alloys by replacing rare elements with less expensive elements etc. New alloys like tantalum, niobium, zirconium, and magnesium are receiving attention given their satisfying mechanical and biological properties. Non‐oxide ceramics like silicon nitride and silicon carbide are being currently developed as a promising implant material possessing a combination of properties such as good wear and corrosion resistance, increased ductility, good fracture and creep resistance, and relatively high hardness in comparison to alumina. Polymer/magnesium composites are being developed to improve mechanical properties as well as retain polymer's property of degradation. Recent advances in orthobiologics are proving interesting as well. This paper thus deals with the latest improvements being made to the existing implant materials and includes new materials being introduced in the field of biomaterials. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 101A: 3349–3364, 2013.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.34605

Cites

96 of 96 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 96 references

Cited by

See all 273

Metadata

Authors
Mantripragada, V. P., Lecka‐Czernik, B., Ebraheim, N. A., & Jayasuriya, A. C.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2013-06-14
Volume
101
Issue
11
Pages
3349-3364
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2147393041
Cited by
273
References
96
FWCI
15.87
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An overview of recent advances in designing orthopedic and craniofacial implants. https://app.cochat.ai/papers/10.1002/jbm.a.34605
The paper
Mantripragada, V. P., Lecka‐Czernik, B., Ebraheim, N. A., & Jayasuriya, A. C. (2013). An overview of recent advances in designing orthopedic and craniofacial implants. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.34605

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.