The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Performance of conical abutment (Morse Taper) connection implants: A systematic review
Abstract
In this systematic review, we aimed to compare conical versus nonconical implant–abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: “dental implant” AND “dental abutment” AND (“conical” OR “taper” OR “cone”). Names of the most common conical implant–abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty‐two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta‐analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant–abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 552–574, 2014.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156
Cited by
Basis of bone metabolism around dental implants during osseointegration and peri‐implant bone loss
Insua, A., Monje, A., Wang, H., & Miron, R. J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36060 · Cited by 277
Metadata
- Authors
- Schmitt, C. M., Nogueira‐Filho, G., Tenenbaum, H. C., Lai, J. Y., Brito, C., Döring, H., & Nonhoff, J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2013-05-09
- Volume
- 102
- Issue
- 2
- Pages
- 552-574
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1565481913
- Cited by
- 261
- References
- 1
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of conical abutment (Morse Taper) connection implants: A systematic review. https://app.cochat.ai/papers/10.1002/jbm.a.34709
- The paper
- Schmitt, C. M., Nogueira‐Filho, G., Tenenbaum, H. C., Lai, J. Y., Brito, C., Döring, H., & Nonhoff, J. (2014). Performance of conical abutment (Morse Taper) connection implants: A systematic review. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.34709
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.