Biocompatibility and biodegradation of protein microparticle and film scaffolds made from kafirin (sorghum prolamin protein) subcutaneously implanted in rodent models
Abstract
Kafirin, the sorghum prolamin protein, like its maize homologue zein, can be made into microparticles and films and potentially used as a biomaterial. Zein has good bio- and cyto-compatibility. Kafirin could be advantageous as it is more hydrophobic, more crosslinked, more slowly digested by mammalian proteases than zein and is non-allergenic. The safety and biocompatibility of kafirin implants in two forms was determined in rodent models. One week post subcutaneous injection of kafirin microparticles (size 5-µm diameter) in mice, chronic inflammation, abnormal red blood cells, and gross fibrin formation were observed. This chronic inflammatory response was possibly caused by the release of hydrolysis products such as glutamate during the degradation of the kafirin microparticles. In contrast, films made from kafirin microparticles (50-µm thick, folded into 1 cm(3) ) implanted in rats showed no abnormal inflammatory reactions and were only partially degraded by day 28. The slower degradation of the kafirin films was probably due to their far smaller surface area when compared to kafirin microparticles. Thus, kafirin films appear to have potential as a biomaterial. This study also raises awareness that the form of prolamin based biomaterials, (kafirin and zein) should be considered when assessing the safety of such materials.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Immunohistochemical analysis showed that the expression of inflammatory markers CD68 and CD3 peaked at approximately 2 weeks and subsequently declined, while the macrophage M1/M2 ratio decreased from 2.1 to 0.6.
“Immunohistochemical analysis showed that the expression of inflammatory markers CD68 and CD3 peaked at approximately 2 weeks and subsequently declined, while the macrophage M1/M2 ratio decreased from 2.1 to 0.6.”
From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [106]
Data from a New Zealand rabbit tibial implantation model demonstrated favorable host responses to PDA-modified titanium alloy screws.
“With respect to in vivo tissue compatibility, data from a New Zealand rabbit tibial implantation model demonstrated favorable host responses to PDA-modified titanium alloy screws.”
From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [106]
Histological analysis at 4, 12, and 26 weeks post-implantation revealed only mild, localized mononuclear cell infiltration on hematoxylin and eosin staining, without the formation of thick fibrous capsules (<50 μm).
“Histological analysis at 4, 12, and 26 weeks post-implantation revealed only mild, localized mononuclear cell infiltration on hematoxylin and eosin staining, without the formation of thick fibrous capsules (<50 µm).”
From Polydopamine-Based Biomaterials in Oral Medicine: Applications, Mechanisms, and Translational Challenges (2026) · cites this paper as [106]
Cited by
Sorted by citations
Yang, Z., Song, W., Lv, L., Zhai, S., Liu, Y., Cui, H., Li, X., Gao, F., & Chu, S. (2026) · International Journal of Nanomedicine · doi:10.2147/ijn.s611922
“1,20,106 Taken together, existing evidence supports the conclusion that PDA-based materials exhibit favorable cytocompatibility and tissue tolerance.”
- Authors
- Taylor, J., Anyango, J. O., Potgieter, M., Kallmeyer, K., Naidoo, V., Pepper, M. S., & Taylor, J. R. N.
- Affiliations
- University of Pretoria (ZA)
- Egerton University (KE)
- Corresponding author
- Taylor, John R. N.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2014-12-29
- Volume
- 103
- Issue
- 8
- Pages
- 2582-2590
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1960993339
- Cited by
- 18
- References
- 0
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 3
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- UpSpace Institutional Repository (University of Pretoria) (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- kafirin, zein, protein microparticles, protein films, biocompatibility, biodegradation, subcutaneous implantation, chronic inflammation, fibrin formation, glutamate release, biomaterial safety
- MeSH terms
- Animals, Biocompatible Materials, Injections, Subcutaneous, Male, Mice, Inbred BALB C, Plant Proteins, Proteins, Models, Animal, Mice, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review