Cited by 18biodegradable polymer synthesis and propertiesSilk-based biomaterials and applicationsBone Tissue Engineering Materials

Biocompatibility and biodegradation of protein microparticle and film scaffolds made from kafirin (sorghum prolamin protein) subcutaneously implanted in rodent models

Taylor, Janet, Anyango, Joseph O., Potgieter, Marnie, Kallmeyer, Karlien, Naidoo, Vinny, Pepper, Michael S., Taylor, John R. N.·2015·Journal of Biomedical Materials Research Part A

Abstract

Kafirin, the sorghum prolamin protein, like its maize homologue zein, can be made into microparticles and films and potentially used as a biomaterial. Zein has good bio- and cyto-compatibility. Kafirin could be advantageous as it is more hydrophobic, more crosslinked, more slowly digested by mammalian proteases than zein and is non-allergenic. The safety and biocompatibility of kafirin implants in two forms was determined in rodent models. One week post subcutaneous injection of kafirin microparticles (size 5-µm diameter) in mice, chronic inflammation, abnormal red blood cells, and gross fibrin formation were observed. This chronic inflammatory response was possibly caused by the release of hydrolysis products such as glutamate during the degradation of the kafirin microparticles. In contrast, films made from kafirin microparticles (50-µm thick, folded into 1 cm(3) ) implanted in rats showed no abnormal inflammatory reactions and were only partially degraded by day 28. The slower degradation of the kafirin films was probably due to their far smaller surface area when compared to kafirin microparticles. Thus, kafirin films appear to have potential as a biomaterial. This study also raises awareness that the form of prolamin based biomaterials, (kafirin and zein) should be considered when assessing the safety of such materials.

Integrity signals

Registry

Crossref · 10.1002/jbm.a.35394

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Immunohistochemical analysis showed that the expression of inflammatory markers CD68 and CD3 peaked at approximately 2 weeks and subsequently declined, while the macrophage M1/M2 ratio decreased from 2.1 to 0.6.

    “Immunohistochemical analysis showed that the expression of inflammatory markers CD68 and CD3 peaked at approximately 2 weeks and subsequently declined, while the macrophage M1/M2 ratio decreased from 2.1 to 0.6.”
  • Data from a New Zealand rabbit tibial implantation model demonstrated favorable host responses to PDA-modified titanium alloy screws.

    “With respect to in vivo tissue compatibility, data from a New Zealand rabbit tibial implantation model demonstrated favorable host responses to PDA-modified titanium alloy screws.”
  • Histological analysis at 4, 12, and 26 weeks post-implantation revealed only mild, localized mononuclear cell infiltration on hematoxylin and eosin staining, without the formation of thick fibrous capsules (<50 μm).

    “Histological analysis at 4, 12, and 26 weeks post-implantation revealed only mild, localized mononuclear cell infiltration on hematoxylin and eosin staining, without the formation of thick fibrous capsules (<50 µm).”

Cited by

Sorted by citations

Authors
Taylor, J., Anyango, J. O., Potgieter, M., Kallmeyer, K., Naidoo, V., Pepper, M. S., & Taylor, J. R. N.
Affiliations
  • University of Pretoria (ZA)
  • Egerton University (KE)
Corresponding author
Taylor, John R. N.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2014-12-29
Volume
103
Issue
8
Pages
2582-2590
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1960993339
Cited by
18
References
0
Citations by year
2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 3
FWCI
0.63
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research Part A (publishedVersion)
  • PubMed (publishedVersion)
  • UpSpace Institutional Repository (University of Pretoria) (submittedVersion)
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
kafirin, zein, protein microparticles, protein films, biocompatibility, biodegradation, subcutaneous implantation, chronic inflammation, fibrin formation, glutamate release, biomaterial safety
MeSH terms
Animals, Biocompatible Materials, Injections, Subcutaneous, Male, Mice, Inbred BALB C, Plant Proteins, Proteins, Models, Animal, Mice, Tissue Scaffolds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review