Preparation of a porous conductive scaffold from aniline pentamer-modified polyurethane/PCL blend for cardiac tissue engineering: PREPARATION OF A POROUS CONDUCTIVE SCAFFOLD FROM POLYURETHANE/PCL BLEND
Open accessThe DOI matches its Crossref record.
Abstract
A novel biodegradable electroactive polyurethane containing aniline pentamer (AP) was blended with polycaprolactone (PCL). The prepared blend (PB) and PCL were further fabricated in to scaffolds using a mixture of poly(ethylene glycol) and salt particles in a double porogen particulate leaching and compression molding methodology. Scaffolds held open and interconnected pores having pore size ranging from several μm to 150 µm. PB scaffolds had compression modulus and strength of 4.1 and 1.3 MPa, respectively. The conductivity of the scaffold was measured as 10(-5) ± 0.09 S .cm(-1) and preserved for at least 100 h post fabrication. Scaffolds supported neonatal cardiomyocytes adhesion and growth with PB showing more extensive effect on the expression of the cardiac genes involved in muscle contraction and relaxation (troponin-T) and cytoskeleton alignment (actinin-4). Our results highlight the potential of incorporation of AP as an electroactive moiety for induction of cardiomyocyte proliferation and repair of damaged heart tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PCL-Based Composite Scaffold Matrices for Tissue Engineering Applications
Siddiqui, N., Asawa, S., Birru, B., Baadhe, R., & Rao, S. (2018) · Molecular Biotechnology · doi:10.1007/s12033-018-0084-5 · Cited by 461
Conductive biomaterials for muscle tissue engineering
Dong, R., Ma, P. X., & Guo, B. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119584 · Cited by 381
Biobased polyurethanes for biomedical applications
Wendels, S., & Avérous, L. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.10.002 · Cited by 379
Electroactive polymers for tissue regeneration: Developments and perspectives
Ning, C., Zhou, Z., Tan, G., Zhu, Y., & Mao, C. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.01.001 · Cited by 346
Electrically Conductive Materials: Opportunities and Challenges in Tissue Engineering
Saberi, A., Jabbari, F., Zarrintaj, P., Saeb, M. R., & Mozafari, M. (2019) · Biomolecules · doi:10.3390/biom9090448 · Cited by 237
Metadata
- Authors
- Baheiraei, N., Yeganeh, H., Ai, J., Gharibi, R., Ebrahimi-Barough, S., Azami, M., Vahdat, S., & Baharvand, H.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2015-03-30
- Volume
- 103
- Issue
- 10
- Pages
- 3179-3187
- ISSN
- 1549-3296 (ISSN-L)
- OpenAlex
- W2144320863
- Cited by
- 116
- References
- 0
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparation of a porous conductive scaffold from aniline pentamer-modified polyurethane/PCL blend for cardiac tissue engineering: PREPARATION OF A POROUS CONDUCTIVE SCAFFOLD FROM POLYURETHANE/PCL BLEND. https://app.cochat.ai/papers/10.1002/jbm.a.35447
- The paper
- Baheiraei, N., Yeganeh, H., Ai, J., Gharibi, R., Ebrahimi-Barough, S., Azami, M., Vahdat, S., & Baharvand, H. (2015). Preparation of a porous conductive scaffold from aniline pentamer-modified polyurethane/PCL blend for cardiac tissue engineering: PREPARATION OF A POROUS CONDUCTIVE SCAFFOLD FROM POLYURETHANE/PCL BLEND. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.35447
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.