The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Effect of porosity on the fluid flow characteristics and mechanical properties of tantalum scaffolds
Abstract
In many cases of traumatic bone injury, bone grafting is required. The primary source of graft material is either autograft or allograft. The use of both material sources are well established, however, both suffer limitations. In response, many grafting alternatives are being explored. This article specifically focuses on a porous tantalum metal grafting material (Trabecular Metal™) marketed by Zimmer. Twenty‐one cylindrical scaffolds were manufactured (66% to 88% porous) and tested for porosity, intrinsic permeability, tangent elastic modulus, and for yield stress and strain behavior. Scaffold microstructural geometries were also measured. Tantalum scaffold intrinsic permeability ranged from 2.1 × 10−10 to 4.8 × 10−10 m 2 and tangent elastic modulus ranged from 373 MPa to 2.2 GPa. Both intrinsic permeability and tangent elastic modulus closely matched porosity‐matched cancellous bone specimens from a variety of species and anatomic locations. Scaffold yield stress ranged from 4 to 12.7 MPa and was comparable to bovine and human cancellous bone. Yield strain was unaffected by scaffold porosity (average = 0.010 mm/mm). Understanding these structure–function relationships will help complete the basic physical characterization of this new material and will aid in the development of realistic mathematical models, ultimately enhancing future implant designs utilizing this material. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Yield Behavior of Bovine Cancellous Bone
Turner, C. H. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168375 · Cited by 127
Cited by
Biomimetic porous scaffolds for bone tissue engineering
Wu, S., Liu, X., Yeung, K. W. K., Liu, C., & Yang, X. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.04.001 · Cited by 1,159
Bobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
Biomaterials for bone tissue engineering scaffolds: a review
Qu, H., Fu, H., Han, Z., & Sun, Y. (2019) · RSC Advances · doi:10.1039/c9ra05214c · Cited by 827
Additively manufactured porous tantalum implants
Wauthle, R., van der Stok, J., Amin Yavari, S., Van Humbeeck, J., Kruth, J.-P., Zadpoor, A. A., Weinans, H., Mulier, M., & Schrooten, J. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.12.003 · Cited by 417
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
Metadata
- Authors
- Shimko, D. A., Shimko, V. F., Sander, E. A., Dickson, K. F., & Nauman, E. A.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2005-02-25
- Volume
- 73B
- Issue
- 2
- Pages
- 315-324
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2143228580
- Cited by
- 215
- References
- 4
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.